Netgear M4300-24X24F (XSM4348S) - Stackable Managed Switch with 48x10G including 24x10GBASE-T and 24xSFP+ Layer 3 Guia Do Programa

Página de 1143
Switching Commands 
480
M4200 and M4300 Series ProSAFE Managed Switches 
show mrp
This command displays MRP leave, join, and leaveall intervals configured on interfaces. If 
you specify the summary parameter, the output shows interval values for all interfaces. If you 
specify the unit/slot/port parameter, the output shows the MRP intervals for the 
specified interface.
MMRP Commands
mmrp (Global Config)
Use this command in Global Config mode to enable MMRP. MMRP must also be enabled on 
the individual interfaces.
Parameter
Description
jointime seconds
The interval between the transmission of MRP PDUs registering (or reregistering) membership for 
an attribute. There is an instance of this timer on a per-port, per-MRP participant basis. 
Permissible values are 10 to 100 centiseconds (0.1 to 1.0 seconds). The factory default is 
20 centiseconds (0.2 seconds). The finest granularity of specification is one centisecond 
(0.01 seconds).
leavetime seconds
The period of time to wait after receiving an unregister request for an attribute before deleting the 
attribute. You can consider this a buffer time for another station to assert registration for the same 
attribute in order to maintain uninterrupted service. There is an instance of this timer on a 
per-Port, per-MRP participant basis. Permissible values are 20 to 600 centiseconds (0.2 to 
6.0 seconds). The factory default is 300 centiseconds (3.0 seconds). 
leavealltime seconds The LeaveAllTime controls how frequently LeaveAll PDUs are generated. A LeaveAll PDU 
indicates that all registrations are shortly to be deregistered. Participants must to rejoin in order to 
maintain registration. There is an instance of this timer on a per-port, per-MRP participant basis. 
The Leave All Period Timer is set to a random value in the range of LeaveAllTime to 
1.5*LeaveAllTime. Permissible values are 200 to 6000 centiseconds (2 to 60 seconds). The 
factory default is 2000 centiseconds (20 seconds).
Format
show mrp interface {summary | unit/slot/port}
Mode
Privileged Exec
Default
disabled
Format
mmrp
Mode
Global Config