Netgear M4300-24X24F (XSM4348S) - Stackable Managed Switch with 48x10G including 24x10GBASE-T and 24xSFP+ Layer 3 Guia Do Administrador

Página de 688
DHCPv6 Server 
489
 Managed Switches
3. 
Enable DHCPv6 service on VLAN 1.
4. 
Configure a static route for 2001:2::/64.
Configure the DHCPv6 Relay
1. 
Enable IPv6 routing.
2. 
On the DHCPv6 relay, configure the interface that is connected to the DHCPv6 server.
(Netgear Switch) (Config)#interface vlan 1 
(Netgear Switch) (Interface vlan 1)#ipv6 address 2001:1::1/64 
(Netgear Switch) (Interface vlan 1)#ipv6 enable 
(Netgear Switch) (Interface vlan 1)#ipv6 dhcp server pool1 preference 20 
(Netgear Switch) (Interface vlan 1)#exit 
(Netgear Switch) (Config)#interface 1/0/20 
(Netgear Switch) (Interface 1/0/20)#vlan pvid 1 
(Netgear Switch) (Interface 1/0/20)#vlan participation include 1 
(Netgear Switch) (Interface 1/0/20)#exit 
(Netgear Switch) (Config)#ipv6 route 2001:2::/64 2001:1::2
(Netgear Switch) (Config)#exit 
(Netgear Switch) (Config)#ip routing 
(Netgear Switch) (Config)#ipv6 unicast-routing 
(Netgear Switch) (Config)#interface vlan 1 
(Netgear Switch) (Interface vlan 1)#ipv6 address 2001:1::2/64 
(Netgear Switch) (Interface vlan 1)#ipv6 enable 
(Netgear Switch) (Interface vlan 1)#exit 
(Netgear Switch) (Config)#interface 1/0/20 
(Netgear Switch) (Interface 1/0/20)#vlan pvid 1 
(Netgear Switch) (Interface 1/0/20)#vlan participation include 1 
(Netgear Switch) (Interface 1/0/20)#exit