Netgear M4300-24X24F (XSM4348S) - Stackable Managed Switch with 48x10G including 24x10GBASE-T and 24xSFP+ Layer 3 Manual Do Utilizador

Página de 700
Configure System Information 
26
M4200 and M4300 Series ProSAFE Managed Switches Web Management User Manual 
The new password does not display as you type it; only dots are shown to hide the entry. 
The password is from 8 to 64 alphanumeric characters in length and is case-sensitive.
9. 
In the Enable Password field, enter the new password for the enable mode in the 
command-line interface. 
The new password does not display as you type it; only dots are shown to hide the entry. 
The password is from 8 to 64 alphanumeric characters in length and is case-sensitive.
10. 
In the System Name field, type the name to identify this switch. 
You can use a name up to 255 characters in length. The factory default is blank.
11. 
In the System Location field, type the location of the switch. 
You can use a location up to 255 characters in length. The factory default is blank.
12. 
Enter the System Contact, the name of the contact person for this switch. 
You can use a contact name up to 255 characters in length. The factory default is blank.
13. 
In the SNTP mode field, select Enable or Disable.
This specifies the state of the SNTP client. The default value is Disable, and the local 
clock is used to get the time value.
14. 
Specify the address of the SNTP Server.
Enter a text string of up to 64 characters containing the host name of an SNTP server. 
The server address can be IPv4, IPv6, or a host name. The host name resolves into an IP 
address each time an SNTP request is sent to it.
15. 
In the Designated Source Interface list, select Management VLAN or Service Port
This is the source interface that is used for SNMP trap, syslog, DNS, TACACS+, 
RADIUS, sflow, and SNTP applications. By default, Management VLAN is used as the 
source interface. 
Note:
If you select Management VLAN as the source interface, the routing 
mode for the selected VLAN must be enabled.
16. 
Click the Apply button.
The updated configuration is sent to the switch. Configuration changes take effect 
immediately.
Configure the Initial IPv4 Management VLAN
To configure the initial IPv4 management VLAN:
1. 
Launch a web browser.
2. 
Enter http://<ipaddress> in the web browser address field.
The login window opens.
3. 
Enter the user name and password.