Netgear S3300-28X-PoE+ (GS728TXP) - ProSAFE S3300 Smart Switch Series Guia Do Administrador
![Netgear](https://files.manualsbrain.com/attachments/cf1ad5de25a3f8d6c88ef0ab489c1b137eebe11f/common/fit/150/50/17742d1e0cdacf24edeb88c30757620088415c5f7699f69b4517262e21e0/brand_logo.jpeg)
Monitoring the System
278
S3300 Smart Switch
Use the buttons at the bottom of the screen to perform the following actions:
•
To clear all the EAP counters for all ports on the switch, select the check box in the
row heading and click the Clear button. The button resets all statistics for all ports to
default values.
row heading and click the Clear button. The button resets all statistics for all ports to
default values.
•
To clear the counters for a specific port, select the check box associated with the port
and click the Clear button.
and click the Clear button.
•
Click Update to update the page with the latest information on the switch.
Cable Test
Use the Cable Test screen to display information about the cables connected to switch ports.
To perform the cable test:
1.
Select Monitoring
Ports > Cable Test.
2.
Select the check box next to each port on which to run the cable test.
3.
Click the Apply button.
The cable test is run on all selected ports.
The cable test can take up to 2 seconds to complete. If the port has an active link then the
link is not taken down and the cable status is always Normal. The command returns a
cable length estimate if this feature is supported by the PHY for the current link speed.
Note that if the link is down and a cable is attached to a 10/100 Ethernet adapter then the
cable status can be Open or Short because some Ethernet adapters leave unused wire
pairs unterminated or grounded.
link is not taken down and the cable status is always Normal. The command returns a
cable length estimate if this feature is supported by the PHY for the current link speed.
Note that if the link is down and a cable is attached to a 10/100 Ethernet adapter then the
cable status can be Open or Short because some Ethernet adapters leave unused wire
pairs unterminated or grounded.
Response Frames Received
The number of valid EAP Response frames received on the port.
Request/ID Frames
Transmitted
Transmitted
The number of EAP Requested ID frames transmitted through the
port.
port.
Request Frames Transmitted
The number of EAP Request frames transmitted through the port.
Table 95. EAP statistics (continued)
Field
Description