Netgear S3300-28X-PoE+ (GS728TXP) - ProSAFE S3300 Smart Switch Series Guia Do Administrador
![Netgear](https://files.manualsbrain.com/attachments/cf1ad5de25a3f8d6c88ef0ab489c1b137eebe11f/common/fit/150/50/17742d1e0cdacf24edeb88c30757620088415c5f7699f69b4517262e21e0/brand_logo.jpeg)
Maintenance
300
S3300 Smart Switch
Ping IPv6
This screen is used to send a Ping request to a specified Hostname or IPv6 address. You can
use this to check whether the switch can communicate with a particular IPv6 station. Once
you click the APPLY button, the switch will send three pings and the results will be displayed
below the configurable data. The output will be:
use this to check whether the switch can communicate with a particular IPv6 station. Once
you click the APPLY button, the switch will send three pings and the results will be displayed
below the configurable data. The output will be:
Send count=3, Receive count=n from (IPv6 Address). Average round trip
time = n ms.
To access the Ping IPv6 page, click Maintenance
Troubleshooting
Ping IPv6.
1.
Select the Ping type from the list. Possible values are:
•
Global
—
Ping a global IPv6 address.
•
Link Local
—
Pink a link-local IPv6 address over the specified interface. This field is
shown when Interface is selected as the ping option.
2.
Use IPv6 Address/Hostname to enter the IPv6 address or Hostname of the station you
want the switch to ping. The initial value is blank. The IPv6 Address or Hostname you enter
is not retained across a power cycle. The format is xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx.
The maximum number of characters is 255.
want the switch to ping. The initial value is blank. The IPv6 Address or Hostname you enter
is not retained across a power cycle. The format is xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx.
The maximum number of characters is 255.
3.
Use Count to enter the number of echo requests you want to send. The range is 1 to 15.
The default value is 3.
The default value is 3.
4.
Enter the Interval in seconds between ping packets. The range is 1 to 60. The default value
is 3.
is 3.
5.
Use Datagram Size to enter the datagram size. The valid range is 0 to 13000. The default
value is 0 bytes.
value is 0 bytes.
6.
Enter the Source IP address or interface to use when sending the echo request packets. If
source is not required, select None as the source option. Possible values are:
source is not required, select None as the source option. Possible values are:
•
None
—
The source address of the ping packet would be the address of the default
outgoing interface.
•
IPv6 Address
—
The source IPv6 address to use when sending the Echo request
packets. This field is shown when IPv6 Address is selected as the source option.
•
Interface
—
The interface to use when sending the Echo request packets. This field is
shown when Interface is selected as the source option.