Netgear S3300-28X-PoE+ (GS728TXP) - ProSAFE S3300 Smart Switch Series Guia Do Administrador
![Netgear](https://files.manualsbrain.com/attachments/cf1ad5de25a3f8d6c88ef0ab489c1b137eebe11f/common/fit/150/50/17742d1e0cdacf24edeb88c30757620088415c5f7699f69b4517262e21e0/brand_logo.jpeg)
Configure System Information
58
S3300 Smart Switch
To change the host name or IP address in an entry:
1.
Select the check box next to the entry to update.
2.
Enter the new information in the appropriate field.
3.
Click the Apply button.
Green Ethernet
Use this screen to configure Green Ethernet features. Using the Green Ethernet
Configuration features allows for power consumption savings.
Configuration features allows for power consumption savings.
To configure the Green Ethernet settings:
1.
Select System
Management
Green Ethernet
Green Ethernet Configuration.
2.
Enable or disable the Auto Power Down mode.
•
Enable. When the port link is down, the PHY (physical layer device) will automatically
go down for a short period of time and then wake up to check link pulses. This allows
the port to continue to perform autonegotiation while consuming less power when no
link partner is present.
go down for a short period of time and then wake up to check link pulses. This allows
the port to continue to perform autonegotiation while consuming less power when no
link partner is present.
•
Disable. Provide full power to the PHY even if the port link is down. The default is
Disable.
Disable.
3.
Enable or disable the EEE mode.
•
Enable. When the send and receive sides of a link are lightly loaded, the port can
transition to low power mode to save power.
transition to low power mode to save power.
•
Disable. Provide full power to the PHY regardless of the link load. The default is
Disable.
Disable.
4.
Click the Apply button.
Green Ethernet Interface Configuration
Use this screen to configure per-port Green Ethernet settings.
To configure the Green Ethernet Interface settings:
1.
Select System
Management
Green Ethernet
Green Ethernet Interface
Configuration.
2.
Select one or more ports to configure.
•
To configure a single port, select the check box associated with it, or type the port
number in the Go To Interface field and click the Go button.
number in the Go To Interface field and click the Go button.
•
To configure multiple ports with the same settings, select the check box associated
with each port to configure.
with each port to configure.
•
To configure all ports with the same settings, select the check box in the heading row.
3.
Use the lists to enable or disable the Green Ethernet features for the selected ports:
•
Auto Power Down Mode. The factory default is Disable. If Auto Power Down Mode is
not supported, then N/A (not applicable) is displayed. When this mode is enabled and