Netgear S3300-28X-PoE+ (GS728TXP) - ProSAFE S3300 Smart Switch Series Guia Do Administrador
Configure System Information
77
S3300 Smart Switch
Click Update to update the page with the latest information on the switch.
Advanced PoE Configuration
The Advanced > PoE Configuration screen displays the same table as the Basic > PoE
Configuration screen described above. However the Advanced screen allows you to
configure a host of PoE parameters specific to port(s) of a specific unit.
Configuration screen described above. However the Advanced screen allows you to
configure a host of PoE parameters specific to port(s) of a specific unit.
Advanced PoE Port Configuration
To configure advanced PoE port settings.
1.
Select System
PoE
Advanced
PoE Port Configuration.
The PoE Port Configuration screen displays.
Figure 31. PoE Port Configuration
2.
In the Unit Selection field, select a current PoE unit. You can change the PoE Unit by
selecting another unit ID listed in this field.
selecting another unit ID listed in this field.
3.
Next to Admin Mode, select the Enable button to enable the port to deliver a power. The
factory default is Enable.
factory default is Enable.
4.
Configure the Port Priority. Use this field to determine which ports can deliver power when
total power delivered by the system crosses a certain threshold. The switch may not be able
to supply power to all connected devices. Priority is used to determine which ports can
total power delivered by the system crosses a certain threshold. The switch may not be able
to supply power to all connected devices. Priority is used to determine which ports can
Power Source
The power source currently being used to deliver power - Main AC
or RPS.
or RPS.
Threshold Power
The system can power up one more port if consumed power is less
than Threshold Power. In other words, consumed power can be
between Nominal and Threshold Power values. The Threshold
Power value is effected by changing the System Usage Threshold.
There could be a delay in showing the updated values. Click the
Update button to refresh the page again if the Threshold Power is
not changed accordingly. Threshold Power is displayed in
milliwatts (mW).
than Threshold Power. In other words, consumed power can be
between Nominal and Threshold Power values. The Threshold
Power value is effected by changing the System Usage Threshold.
There could be a delay in showing the updated values. Click the
Update button to refresh the page again if the Threshold Power is
not changed accordingly. Threshold Power is displayed in
milliwatts (mW).
Consumed Power
The total amount of power which is currently being delivered to all
ports in milliwatts.
ports in milliwatts.
Field
Description