Netgear GS752TP - 52PT GE POE SMART SWITCH Guia Do Administrador
![Netgear](https://files.manualsbrain.com/attachments/cf1ad5de25a3f8d6c88ef0ab489c1b137eebe11f/common/fit/150/50/17742d1e0cdacf24edeb88c30757620088415c5f7699f69b4517262e21e0/brand_logo.jpeg)
Monitoring the System
217
GS752TP, GS728TP, and GS728TPP Gigabit Smart Switches
•
Length Error Frames Received. The number of EAPOL frames with an invalid
packet body length received on this port.
packet body length received on this port.
•
Response/ID Frames Received. The number of EAP respond ID frames that have
been received on the port.
been received on the port.
•
Response Frames Received. The number of valid EAP response frames received
on the port.
on the port.
•
Request/ID Frames Transmitted. The number of EAP requested ID frames
transmitted through the port.
transmitted through the port.
•
Request Frames Transmitted. The number of EAP request frames transmitted
through the port.
through the port.
Use the buttons at the bottom of the screen to perform the following actions:
•
To clear all the EAP counters for all ports on the switch, select the check box in the
row heading and click CLEAR. The button resets all statistics for all ports to 0.
row heading and click CLEAR. The button resets all statistics for all ports to 0.
•
To clear the counters for a specific port, select the check box associated with the port
and click CLEAR.
and click CLEAR.
Cable Test
Use the Cable Test screen to display information about the cables connected to switch ports.
To display cable information:
1.
Select Monitoring
Ports
Cable Test.
The following screen displays:
2.
Select the interface for which cable data is to be displayed.