Netgear GS728TPP – 28PT GE POE+ SMART SWITCH Guia Do Administrador

Página de 275
Maintenance 
241
 GS752TP, GS728TP, and GS728TPP Gigabit Smart Switches
The following screen displays:
 
2. 
In the IP Address/Hostname field, specify the IP address or the host name of the station you 
want the switch to ping. 
The initial value is blank. This information is not retained across a power cycle.
3. 
Optionally, configure the following settings:
Probes Per Hop. Specify the number of times each hop must be probed. The valid 
range is 1–10.
MaxTTL. Specify the maximum time-to-live for a packet in number of hops. The valid 
range is 1–255.
InitTTL. Specify the initial time-to-live for a packet in number of hops. The valid range 
is 1–255.
MaxFail. Specify the maximum number of failures allowed in the session. The valid 
range is 0–255.
Interval. Specify the time between probes in seconds. The valid range is 1–60.
Port. Specify the UDP destination port in probe packets. The valid range is 1–65535.
Size. Specify the size of probe packets. The valid range is 64–1472.
4. 
Click APPLY to initiate the traceroute. The results display in the Results field.
Remote Diagnostics
The Remote Diagnostics screen lets you enable Telnet for diagnostic purposes.
To configure the remote diagnostics feature:
1. 
Select Maintenance 
 Troubleshooting 
 Remote Diagnostics.