Netgear GS724TR – 24-Port ProSAFE Gigabit Smart Switch with Static Routing Guia Do Programa

Página de 276
GS700TR Smart Switch Software Administration Manual
8-14
Maintenance
v1.0, May, 2008
2. Click Cancel to cancel the operation on the screen and reset the data on the screen to the latest 
value of the switch.
3. Click Apply to initiate the traceroute. The results display in the TraceRoute box.
Figure 8-10
Table 8-7. TraceRoute Fields
Field
Definition
Hostname/IP 
Address
Enter the IP address or the hostname of the station you want the switch to 
discover path for.
Probes Per Hop
Enter the number of times each hop should be probed. The valid range is 1 to 
10.
MaxTTL
Enter the maximum time-to-live for a packet in number of hops. The valid range 
is 1 to 255.
InitTTL
Enter the initial time-to-live for a packet in number of hops. The valid range is 0 
to 255.
MaxFail
Enter the maximum number of failures allowed in the session. The valid range is 
0 to 255.
Interval
Enter the time between probes in seconds. The valid range is 1 to 60.
Port
Enter the UDP destination port in probe packets. The valid range is 1 to 65535.
Size
Enter the size of probe packets. The valid range is 0 to 65507.
TraceRoute