Netgear M4100-24G-POE+ (GSM7224P) - ProSAFE Gigabit L2+ Managed Switch Manual Do Utilizador
Monitoring the System
383
M4100 Series Managed Switch
If the system is stacked
•
<15>Aug 24 05:34:05 0.0.0.0-1 MSTP[2110]: mspt_api.c(318) 237 %% Interface 12
transitioned to root state on message age timer expiry.
transitioned to root state on message age timer expiry.
This example indicates a message with severity 7 (15 mod 8) (debug) on a system that is
stacked and generated by component MSTP running in thread ID 2110 on Aug 24
05:34:05 by line 318 of file mstp_api.c. This is the 237th message logged with system IP
0.0.0.0 and task-id 1.
stacked and generated by component MSTP running in thread ID 2110 on Aug 24
05:34:05 by line 318 of file mstp_api.c. This is the 237th message logged with system IP
0.0.0.0 and task-id 1.
•
<15>Aug 24 05:34:05 STK0 MSTP[2110]: mspt_api.c(318) 237 %% Interface 12
transitioned to root state on message age timer expiry.
transitioned to root state on message age timer expiry.
This example indicates a user-level message (1) with severity 7 (debug) on a system that
is not stacked and generated by component MSTP running in thread ID 2110 on Aug 24
05:34:05 by line 318 of file mstp_api.c. This is the 237th message logged. Messages
logged to a collector or relay through syslog use an identical format to the previous
message.
is not stacked and generated by component MSTP running in thread ID 2110 on Aug 24
05:34:05 by line 318 of file mstp_api.c. This is the 237th message logged. Messages
logged to a collector or relay through syslog use an identical format to the previous
message.
•
Total number of Messages: For the message log, only the latest 200 entries are
displayed on the screen.
displayed on the screen.
Enable the Command Log
To enable the command log:
1.
Prepare your computer with a static IP address in the 169.254.100.0 subnet, for
example, 169.254.100.201.
example, 169.254.100.201.
2.
Connect an Ethernet cable from an Ethernet port on your computer to an Ethernet port on
the switch.
the switch.
3.
Launch a web browser.
4.
Enter the IP address of the switch in the web browser address field.
The default IP address of the switch is 169.254.100.100.
The Login screen displays.
5.
Enter the user name and password.
The default admin user name is admin and the default admin password is blank, that is,
do not enter a password.
do not enter a password.
6.
Click the Login button.
The web management interface menu displays.
7.
Select Monitoring
Logs > Command Log Configuration.