KitchenAid 36'' Island-Mount 600 CFM Canopy Hood, Architect® Series II Guia Da Instalação

Página de 32
4
For Non-Vented (Recirculating) Installations, You Will Also 
Need:
Recirculating Kit Part Number W10692909 for non-vented 
(recirculating) installations only. See “Assistance or Service” 
section to order.
6" (15.2 cm) round metal vent duct. Length required is 
determined by ceiling height. 
Parts Supplied
Remove parts from packages. Check that all parts are included.
Hood canopy assembly with ventilator and light bulbs 
installed
Filter—installed in hood canopy
4.2 x 8 mm screws (60)
5 x 45 mm screws (4)
Mounting template
Upper vent covers (2)
Lower vent covers (2)
Vent transition with backdraft damper installed
3.5 x 9.5 mm mounting screws (2)
Plastic vent clips (4)
Upper horizontal support bracket
Horizontal support
Vertical supports (8)
3.5 x 6.5 mm screws (4)
2.9 x 3 mm screws (2)
T-10 Torx
®†
 adapter
T20 Torx adapter
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Have a qualified technician install the range hood. It is the 
installer's responsibility to comply with installation clearances 
specified on the model/serial/rating plate. The model/serial/rating 
plate is located behind the left filter on the rear wall of the vent 
hood.
Canopy hood location should be away from strong draft areas, 
such as windows, doors and strong heating vents. 
Cabinet opening dimensions that are shown must be used. Given 
dimensions provide minimum clearance.
Grounded electrical outlet is required. See “Electrical 
Requirements” section.
Because of the size and weight of this island hood, the chimney 
support must be securely attached to the ceiling.
For plaster or drywall ceilings, the chimney support must be 
attached to joists. If this is not possible, you must build a 
support structure behind the plaster or drywall. The support 
structure must be able to support 80 lbs (36.6 kg).
This range hood is recommended for use with cooktops with a 
maximum total rating of 60,000 BTUs or less.
The range hood is factory-set for venting through the roof.
For non-vented (recirculating) installation see “Non-Vented 
(Recirculating) Installation” in “Install Range Hood” section. 
Recirculation Kit Part Number W10692909 is available from your 
dealer or an authorized parts distributor. 
All openings in ceiling and wall where range hood will be installed 
must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the 
Manufactured Home Construction Safety Standards, Title 24 
CFR, Part 328 (formerly the Federal Standard for Mobile Home 
Construction and Safety, Title 24, HUD, Part 280) or when such 
standard is not applicable, the standard for Manufactured Home 
Installation 1982 (Manufactured Home Sites, Communities and 
Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local 
codes.
Product Dimensions
*Vented installations only
**Non-vented (recirculating) installations only
Installation Dimensions
IMPORTANT:
Minimum distance “C”: 24" (61.0 cm) from electric cooking 
surface.
Minimum distance “C”: 27" (68.6 cm) from gas cooking 
surface.
Suggested maximum distance “C”: 36" (91.4 cm)
†®TORX is a registered trademark of Acument Intellectual Properties, LLC.
A. Ceiling height
B. Hood height from ceiling to bottom of the 
range hood: A - C - D= B
C. 24" (61.0 cm) minimum to 36" (91.4 cm) 
maximum suggested hood height
D. Countertop height
12
¹⁄₄
(31.0 cm)
13
³⁄₁₆
"
(33.5 cm)
*32
¹⁄₂
(82.6 cm)
min.
*46
¹⁄₂
(118.0 cm)
max.
**32
¹⁄₂
(82.6 cm)
min.
**52
⁹⁄₁₆
(133.5 cm)
max.
27" (68.6 cm)
36" (91.2 cm)
42" (106.4 cm)
B
C
A
D