KitchenAid 30" Range Hood with the FIT System Ilustrações Dimensionais

Página de 1
PRODUCT MODEL NUMBERS
Because Whirlpool Corporation includes a continuous commitment to improve our 
products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation 
Instructions packed with product. Specifications subject to change without notice.
UXT5230BF
Ref. W10848282A
06/03/2016
30" (76.2 cm) Range Hood
PRODUCT DIMENSIONS
1" 
(2.5 cm)
9" 
(22.9 cm)
2" 
(5.1 cm)
1" 
(2.5 cm)
INSTALLATION CLEARANCES
A.  18" (45.7 cm) minimum distance from electric cooking surface 
24" (61.0 cm) minimum distance from gas cooking surface  
30" (76.2 cm) suggested maximum above the cooking surface
B.  18" (45.7 cm) minimum clearance - upper cabinet to countertop
C.  30" (76.2 cm) minimum cabinet opening width
D.  12" (30.5 cm) cabinet depth
E.  36" (91.4 cm) base cabinet height
B
A
C
D
E
VENTING METHODS
NOTES:
 
Flexible vent is not recommended. Flexible vent creates both back 
pressure and air turbulence that greatly reduce performance.
 
The vent system is optional for this model.
Vent system can terminate either through the roof or wall. Use 3
1
/
4
" x 10" 
(8.3 x 25.4 cm) rectangular with a maximum vent length of 35 ft (10.7 m) 
or 7" (17.8 cm) or larger round vent with a maximum length of 50 ft (15.2 
m) for vent system.
Top Venting
Wall Venting
A
B
A
B
A.  7" (17.8 cm) round vent 
through roof (purchased 
separately) or 3
1
/
4
" x 10" (8.3 x 
25.4 cm) rectangular vent 
through the roof (purchased 
separately)
B.  Roof cap with damper 
(purchased separately)
A.  7" (17.8 cm) round vent 
through the wall or out the 
top (purchased separately) 
or 3
1
/
4
" x 10" (8.3 x 25.4 cm) 
rectangular vent through the 
wall or out the top (purchased 
separately)
B.  Wall cap with damper 
(purchased separately)
ELECTRICAL REQUIREMENTS
A 120 volt, 60 Hz., AC only, 15-amp, fused electrical circuit is required.