KitchenAid Wall-Mount 600 CFM Exhaust Rating Ilustrações Dimensionais

Página de 1
PRODUCT MODEL NUMBERS
OVERALL DIMENSIONS
CABINET OPENING DIMENSIONS
VENTING REQUIREMENTS
KWCV107M
KWCV167M
Electrical:
120-volt, 60-Hz, AC-only, 15-amp.
electrical supply. Use copper wire only. A time-
delay fuse or circuit breaker and separate circuit is
recommended.
30" and 36" 
Pro Line
™ Series Range Hood
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only.  For complete details, see Installation
Instructions packed with product.  Specifications subject to change without notice.
Ref. 8285349
07-31-03
®
Horizontal wall venting
Vertical roof venting
elbow
wall
cap
Maximum length  
= 35 ft. (10.7 m)
1 — 90° elbow 
=  5  ft. (1.5 m)
8 ft. (2.4 m) straight  =  8  ft. (2.4 m)
1 — wall cap 
=  0  ft. (0 m)
system length 
=13  ft. (3.9 m)
6 ft. (1.8 m)
2 ft.
(0.6 m)
6" (15.2 cm) vent system
To calculate the length of the system
you need, add the equivalent feet for
each vent piece used in the system.
Note: Flexible vent is Not recommended.
If it is used, each foot of flexible vent used
is equivalent to two feet (61 cm) of
straight metal vent when calculating the
vent system length.  (Example: A flexible
elbow equals two standard elbows.)
25-5/8" 
(65.1 cm)
min.
37-1/4" 
(94.6 cm)
max.
overall
chimney
height
21-1/4" 
(54.0 cm)
lower
chimney
height
4-3/4"
(12.1 cm) 
19-1/4" 
(48.9 cm)
10-1/4" 
(26.0 cm)
upper
chimney
11-13/16" 
(30.0 cm)
30" (76.2 cm) model: 29-15/16" (76.0 cm)
36" (91.4 cm) model: 35-3/8" (89.9 cm)
3/8" 
(9.5 mm)
18" (45.7 cm) min.
clearance upper
cabinet to countertop
X
36" (91.4 cm)
countertop height
30" (76.2 cm) or 36" (91.4 cm)
cabinet opening width
(if installed between cabinets)
See
Note
Vent piece 
6" (15.2 cm) round
45° elbow
2.5 feet
(0.8 m)
90° elbow
5.0 feet
(1.5 m)
roof cap
wall
cap
34-5/8" 
(87.9 cm)
min.
42-1/2" 
(108.0 cm)
max.
overall
chimney 
height
26-3/4" 
(67.9 cm)
lower
chimney
height
10-1/4" 
(26.0 cm)
3-9/16" 
(9.1 cm)
vent
opening
on each
side
14-5/8" 
(37.1 cm)
5-5/16" 
(13.5 cm)
2-7/16" 
(6.2 cm)
11-13/16" 
(30.0 cm)
Non-vented (recirculating) 
Kit Nos. 8285505 and 8285506 
chimney dimensions
upper
chimney
Vented installations
min. and max. ceiling or soffit height examples
distance from 
hood to cooking 
surface 
(X)
minimum
maximum
24" (61.0 cm)
7' 6-3/8" (2.30 m)
8' 6" (2.59 m)
26" (66.0 cm)
7' 8-3/8" (2.35 m)
8' 8" (2.64 m)
28" (71.1 cm)
7' 10-3/8" (2.40 m)
8' 10" (2.69 m)
30" (76.2 cm)
8' 3/8" (2.45 m)
9' 0" (2.74 m)
Note:
The hood chimneys are adjustable
and designed to meet varying ceiling or
soffit heights depending on the distance “X
between the bottom of the hood and the
cooking surface. For higher ceilings, 40”
(10.2 cm) chimney extension Kit No. 8285600
or Kit No. 8285601 is available.  The chimney
extension replaces the upper chimney
shipped with the hood. The chimney
extension can be cut as needed. For shorter
ceilings or soffits, the upper chimney can be
cut.
Important:
Minimum distance “X”: 24” (61.0 cm)
Suggested maximum distance “X”: 
30” (76.2 cm)
As shown in charts below:
For vented installations, the chimneys can
be adjusted for ceilings between 7’ 6-3/8”
(2.30 m) and 9’ 0” (2.74 m).
For non-vented (recirculating) installations,
the chimneys can be adjusted for ceilings
between 8’ 3-3/8” (2.45 m) and 9’ 5-1/4”
(2.88 m).
Non-vented (recirculating) installations
min. and max. ceiling or soffit height examples
distance from 
hood to cooking 
surface 
(X)
minimum
maximum
24" (61.0 cm)
8' 3-3/8" (2.52 m)
8' 11-1/4" (2.72 m)
26" (66.0 cm)
8' 5-3/8" (2.57 m)
9' 1-1/4" (2.77 m)
28" (71.1 cm)
8' 7-3/8" (2.63 m)
9' 3-1/4" (2.83 m)
30" (76.2 cm)
8' 9-3/8" (2.68 m)
9' 5-1/4" (2.88 m)
Important:
As hood height (distance X)
increases, hood's venting effectiveness
decreases.