ELECTRICAL REQUIREMENTS
A 120 Volt, 60 Hz., AC only, 15-amp, fused electrical circuit is required.
LOCATION REQUIREMENTS
IMPORTANT: Observe all governing codes and ordinances. Have a qualified
technician install the range hood. It is the installer's responsibility to comply with
installation clearances specified on the model/serial rating plate. The model/serial
rating plate is located inside the range hood on the rear wall of the range hood.
Island hood location should be away from strong draft areas, such as windows,
doors and strong heating vents. 
Cabinet opening dimensions that are shown must be used. Given dimensions
provide minimum clearance.
It is recommended that the hood be fastened into solid wood.
The island hood is factory set for venting through the roof or through the wall.
All openings in ceiling and where island hood will be installed must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the Manufactured Home
Construction Safety Standards, Title 24 CFR, Part 328 (formerly the Federal
Standard for Mobile Home Construction and Safety, Title 24, HUD, Part 280) or
when such standard is not applicable, the standard for Manufactured Home
Installation 1982 (Manufactured Home Sites, Communities and Setups) ANSI
A225.1/NFPA 501A*, or latest edition, or with local codes.
VENTING METHODS
A 6" (15.2 cm) round vent system is needed for installation (not included). A
dual 6" (15.2 cm) round vent system is needed for the 48" (121.9 cm) range
hood. The hood exhaust opening is 6" (15.2 cm) round.
NOTE: Flexible vent is not recommended. Flexible vent creates back pressure and
air turbulence that greatly reduce performance.
Vent system can terminate either through the roof or wall. To vent through a
wall, a 90° elbow is needed.
30" (76.2 cm), 36" (91.4 cm) and 48" (121.9 cm) Commercial Style
Wall-Mount Canopy Range Hood
Because Whirlpool Corporation policy includes a continuous commitment to improve our
products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10233971C
10/22/09
KICU420W
KICU460W
KICU480W
*The 48" (121.9 cm) hood uses two 6" (15.2 cm) round vents or transitions
 to 10" (25.4 cm) round vent using Part Number 4396915.
A. Roof cap
B. 6" (15.2 cm) round vent
A. Wall cap
B. 6" (15.2 cm) round vent
A
A
B*
B*
Roof Venting
Wall Venting
Example vent system
The following example falls within the maximum vent length of
35 ft (10.7 m).
Vent Piece
45° elbow
2.5 ft (0.8 m)
90° elbow
5.0 ft (1.5 m)
1 - 90° elbow
1 - wall cap
8 ft (2.4 m) straight
= 5.0 ft (1.5 m)
= 0.0 ft (0.0 m)
= 8.0 ft (2.4 m)
Length of system
= 13.0 ft (3.9 m)
90  elbow
6 ft (1.8 m)
2 ft
(0.6 m)
Wall cap
Vented Installations
11
¹⁄₃" (28.6 cm)
23
⁹⁄₁₆" (59.9 cm)
36" (91.4 cm),
42" (106.7 cm) or
48" (121.9 cm)
27
⁹⁄₁₆" (70.0 cm)
31
¹⁄₂" (80.0 cm)
          min.  
46³⁄₄" (118.8 cm)
          max.  
23
⁵⁄₈" (60.0 cm)
Page 1 of 2
PRODUCT DIMENSIONS
Calculating Vent System Length
To calculate the length of the system you need, add the equivalent feet
(meters) for each vent piece used in the system.
The maximum equivalent vent lengths are:
6" (15.2 cm) round vent - 35 ft (10.7 m)
7" (17.8 cm) round vent - 40 ft (12.2 m)
8" (20.3 cm) round vent - 50 ft (15.2 m)
9" (22.9 cm) and 10" (25.4 cm) round vents - 60 ft (18.3 m)