KitchenAid 15" Width Right-Hand Door Swing Built-In Drain Pump Architect® Series II Ficha De Dados

Página de 6
2
2185944-B
7. Coil power cord of ice maker into a 4" diameter coil.
Wrap electrical tape around the power cord in several
places to keep the cord in a coil. Lay the coiled power
cord on top of the pump over the check valve and plug
in the receptacle of the drain pump. See Figure 2.
Pump
mounting
tab
Figure 3
Figure 2
Vent tube
Pump mounting
screws,
#8-32 x 
3
8
" (2)
Drain tube
(pump to
household
drain)
Drain pump
Power
cord
Power cord
clamp and
screw
Coil ice maker
power cord in
4" diameter.
Tape together
and lay on top
of pump over
the check valve
5
8
" Hose
clamps (2)
8. Attach 
3
8
" ID x 10' drain tube to pump check valve outlet
using 
5
8
" hose clamp. See Figure 2. Use wire tie as a
relief, secure the household drain tube to heat exchanger.
9. Install drain pump. Carefully slide in aligning the tab on
pump to rectangular slot in the unit base. You may need
to tip the pump downward in the front to slip in the slot.
See Figure 3.
10. Connect drain tube to ice maker bin (
5
8
" ID x 5
1
8
") to
pump reservoir inlet using one (1) 
7
8
" adjustable clamp.
See Figure 1.
11. Line up the two (2) screw holes at the rear of pump.
Use two (2) #8-32 x 
3
8
" screws supplied. See Figure 2.
w
WARNING
Electrical Shock Hazard
Connect green ground wire to ground screw.
Failure to do so can result in death or
electrical shock.
(continued)
12. Attach the drain pump power cord to ice maker unit
base with clamp and ground screw used to attach ice
maker power cord from step 6. See Figure 2.