KitchenAid 30" Wall-Mount Canopy Hood Ilustrações Dimensionais

Página de 2
PRODUCT MODEL NUMBERS
VENTING REQUIREMENTS
KWCU505W
KWCU565W
Electrical:
120 volt, 60 Hz, AC only, 15-amp.
electrical supply.
30" (76.2 cm) and 36" (91.4 cm) Canopy Range Hood
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10268948C
11/16/09
This canopy range hood is factory set for venting
through the roof or through the wall.
A 6" (15.2 cm) round vent system is needed for
installation (not included). The hood exhaust
opening is 6" (15.2 cm) round.
NOTE: 
Flexible vent is not recommended. Flexible
vent creates back pressure and air turbulence that
greatly reduce performance.
Vent system can terminate either through the roof
or wall. To vent through a wall, a 90° elbow is
needed.
Rear discharge
A 90° elbow may be installed immediately above
the hood.
For non-vented (recirculating)
installations
If it is not possible to vent cooking fumes and
vapors to the outside, the hood can be used in the
non-vented (recirculating) version, fitting an
activated carbon filter and the diverter. Fumes and
vapors are recycled through the top grille.
NOTE: 
Non-vented (recirculating) installation is
not allowed over cooktops with BTU ratings of
60,000 or higher.
A. Roof cap
B. 6" (15.2 cm) 
round vent
A. Wall cap
B. 6" (15.2 cm) 
round vent
A. Diverter
B. 6" (15.2 cm) 
round vent 
extension
A
A
B
B
B
A
Roof Venting        Wall Venting       Non-vented 
(recirculating)
Calculating Vent System Length
To calculate the length of the system you need, add
the equivalent feet (meters) for each vent piece
used in the system.
Vent Piece 
6" (15.2 cm) Round
45° elbow 2.5 
ft
(0.8 m)
90° elbow 5.0 
ft
(1.5 m)
Maximum equivalent vent length is 35 ft (10.7 m).
90  elbow
6 ft (1.8 m)
2 ft
(0.6 m)
Wall 
cap
The following example falls within the maximum recommended vent length of
35 ft (10.7 m).
1 - 90° elbow 
= 5.0 ft (1.5 m)
1 - wall cap 
= 0.0 ft (0.0 m)
8 ft (2.4 m) straight 
= 8.0 ft (2.4 m)
Length of system 
= 13.0 ft (3.9 m)
Example vent system
LOCATION REQUIREMENTS
IMPORTANT: 
Observe all governing codes and ordinances.
Have a qualified technician install the range hood. It is the installer's responsibility to comply with
installation clearances specified on the model/serial rating plate. The model/serial rating plate is
located inside the range hood on the rear wall of the range hood.
Canopy range hood location should be away from strong draft areas, such as windows, doors and
strong heating vents.
Cabinet opening dimensions that are shown must be used. Given dimensions provide minimum
clearance.
Grounded electrical outlet is required. See “Electrical Requirements” section.
The canopy range hood is factory set for venting through the roof or through the wall. For non-
vented (recirculating) Installation see “Non-vented (recirculating) Installations” in “Prepare
Location” section. Recirculation Kit Part Number W10271501 is available from your dealer or an
authorized parts distributor.
All openings in ceiling and wall where canopy range hood will be installed must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the Manufactured Home Construction Safety
Standards, Title 24 CFR, Part 328 (formerly the Federal Standard for Mobile Home Construction
and Safety, Title 24, HUD, Part 280) or when such standard is not applicable, the standard for
Manufactured Home Installation 1982 (Manufactured Home Sites, Communities and Setups) ANSI
A225.1/NFPA 501A*, or latest edition, or with local codes.
Page 1 of 2