KitchenAid 48-Inch Commercial-Style Series Island-Mount Canopy Hood Ilustrações Dimensionais

Página de 2
36" (91.4 cm) and 48" (121.9 cm) Designer Commercial Style
Island-Mount Canopy Range Hood
Because Whirlpool Corporation policy includes a continuous commitment to improve our
products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10331010C
9/13/12
®
Page 1 of 2
PRODUCT MODEL NUMBERS
ELECTRICAL REQUIREMENTS
A 120 Volt, 60 Hz., AC only, 15-amp, fused electrical circuit is required.
LOCATION REQUIREMENTS
IMPORTANT: Observe all governing codes and ordinances. Have a qualified
technician install the range hood. It is the installer's responsibility to comply with
installation clearances specified on the model/serial rating plate. The model/serial
rating plate is located inside the range hood on the rear wall of the range hood.
Island hood location should be away from strong draft areas, such as windows,
doors and strong heating vents. 
Cabinet opening dimensions that are shown must be used. Given dimensions
provide minimum clearance.
It is recommended that the hood be fastened into solid wood.
The island hood is factory set for venting through the roof or through the wall.
All openings in ceiling and where island hood will be installed must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the Manufactured Home
Construction Safety Standards, Title 24 CFR, Part 328 (formerly the Federal
Standard for Mobile Home Construction and Safety, Title 24, HUD, Part 280) or
when such standard is not applicable, the standard for Manufactured Home
Installation 1982 (Manufactured Home Sites, Communities and Setups) ANSI
A225.1/NFPA 501A*, or latest edition, or with local codes.
VENTING REQUIREMENTS
● 
Vent system must terminate to the outside.
● 
Do not terminate the vent system in an attic or other enclosed area.
● 
Do not use 4" (10.2 cm) laundry-type wall caps.
● 
Use metal vent only. Rigid metal vent is recommended. Do not use plastic or
metal foil vent.
● 
The vent system must have a damper. If the roof or wall cap has a damper, do
not use the damper supplied with the range hood.
KXI9736Y
KXI9748Y
A. Roof cap
B. 6" (15.2 cm) round vent
A. Wall cap
B. 6" (15.2 cm) round vent
A
A
B
B
Roof Venting
Wall Venting
Example vent system
The following example falls within the maximum vent length of
60 ft (18.3 m).
Vent Piece
45° elbow
2.5 ft (0.8 m)
90° elbow
5.0 ft (1.5 m)
1 - 90° elbow
1 - wall cap
8 ft (2.4 m) straight
= 5.0 ft (1.5 m)
= 0.0 ft (0.0 m)
= 8.0 ft (2.4 m)
Length of system
= 13.0 ft (3.9 m)
90  elbow
6 ft (1.8 m)
2 ft
(0.6 m)
Wall cap
Vented Installations
12
¹³⁄₁₆
" (32.6 cm)
23
¹⁵⁄₁₆
"
(60.8 cm
)
36" (91.4 cm) or
48" (121.9 cm)
27
⁹⁄₁₆
" (70.0 cm)
44
¹⁵⁄₁₆
" (114.1 cm) max.
31
¹⁄₂
" (80 cm) min.
19" (48.2 cm)
PRODUCT DIMENSIONS
Calculating Vent System Length
To calculate the length of the system you need, add the equivalent feet
(meters) for each vent piece used in the system.
The maximum equivalent vent length is:
10" (25.4 cm) round vents - 60 ft (18.3 m)
VENTING METHODS
Typical Internal Blower Motor System Venting Installations
A 10" (25.4 cm) round vent system is needed for installation (not included). The
hood exhaust opening is 10" (25.4 cm) round.
NOTE: Flexible vent is not recommended. Flexible vent creates back pressure
and air turbulence that greatly reduce performance.
Vent system can terminate either through the roof or wall. To vent through a
wall, a 90° elbow is needed.