Xerox WorkCentre 5865/5875/5890 Guia Do Administrador

Página de 276
Network Connectivity 
 
60 
Xerox
®
 WorkCentre
®
 5800/5800i Series Multifunction Printer 
 
System Administrator Guide 
 
Raw TCP/IP Printing 
Raw TCP/IP is used to open a TCP socket-level connection over Port 9100, and stream a print-ready file 
to the printer input buffer. It then closes the connection either after sensing an End Of Job character in 
the PDL or after expiration of a preset timeout value. Port 9100 does not require an LPR request from the 
computer or the use of an LPD running on the printer. Raw TCP/IP printing is selected in Windows as the 
Standard TCP/IP port. 
 
Configuring Raw TCP/IP Settings 
1.
  In Xerox
®
 CentreWare
®
 Internet Services, click 
Properties > Connectivity > Setup
2.
  For Protocol, next to Raw TCP/IP Printing, click Edit
3.
  On the Raw TCP/IP Printing tab, for Protocol, select Enabled
4.
  For TCP Port Number, ensure that Port 1 is set to 9100
Note: 
To emulate HP JetDirect EX Plus 3, set Port 2 to 
9101 and Port 3 to 9102
5.
  Next to Bidirectional, for each active port, select Enabled
6.
  Next to Maximum Connections per Port, for each active port, type a number from 1 through 32. 
7.
  Next to For End of Job Timeout, for each active port, type a time in seconds from 0 through 1800. 
8.
  Next to PDL Switching, for each active port, select Enabled as needed. 
Note: 
PDL Switching allows the printer to switch automatically between multiple supported PDLs 
within a single job. 
9.
  To save the new settings, click Apply
10.
  To return all settings to the default status, click Default All
 
Configuring Raw TCP/IP Advanced Settings 
1.
  On the Raw TCP/IP Printing page, click the Advanced tab. 
2.
  Under Connections, set the following: 
  Set the Maximum Connections per port between 1–32. The default port value is 32. 
  To allow concurrent jobs to process for each port connection, type a number between 0–500 
jobs in each port. Type 
0 to allow unlimited concurrent jobs.   
  To limit the number of jobs that are active for each port connection, type a number between 
0–32768. Type 0 to allow unlimited number of active jobs. 
3.
  Under Job Boundary Determination: 
  Type the End of Job Timeout between 0–1800 seconds to specify the amount of time to pass 
before a job processes with an End of Job character. The default time is 300 seconds. Type 0 to 
disable end of job detection by timeout.