Honeywell HE360 Guia Da Instalação

Página de 20
HE360 HUMIDIFIER AND INSTALLATION KIT
9
69-2517EF—01
TROUBLESHOOTING YOUR HUMIDIFIER
Table 3. Troubleshooting Humidifier.
Problem
What to look for
What to do
Water leakage
Leaking joints.
Shut off water.
Tighten connections.
Brass tubing inserts
Verify that brass tubing inserts are used.
Saddle valve leaking.
Verify rubber pad is installed on saddle valve.
No water to drain.
Electrical
Verify control circuit wiring.
Check all connections.
Humidistat
Turn humidistat up and down and listen for contact 
to click.
Humidifier power
Verify that outlet has power.
Solenoid
After verifying other wiring components, turn on 
furnace fan, turn humidistat up and down, and listen 
for solenoid to click.
Plumbing
Verify plumbing connections.
Check for kinks.
Saddle valve
Verify that needle pierces water line and then backs 
out needle to open valve.
Humidifier
Remove cover and verify that water flows into 
distribution tray.
Drain tubing
Verify no obstructions.
Low humidity
Furnace blower not operating.
• Reset circuit breaker or check for blown fuse.
• Check that the furnace power is on.
• Check all external wiring connections.
• Check the humidity control setting.
• Call a professional heating contractor.
Rapid air changes. Drafts (cold 
air is dry and is an added load 
to the humidifier).
• Keep doors and windows closed.
• Close fireplace damper when not in use.
• Keep exhaust fan running time to a minimum.
• Seal around doors and windows.
High humidity
Condensation on walls.
• Turn off humidity control and water until 
condensation is completely evaporated.
Heavy condensation on 
windows.
• Turn humidity control down low enough to 
eliminate condensation caused by moisture from 
bathing, mopping, cooking, etc. If moisture 
persists, more ventilation is needed.