Honeywell Electrode Humidifier [with HumidiPRO™ H6062 Digital Humidity Control (HM700A1000)] Guia Da Instalação

Página de 80
INSTALLATION INSTRUCTIONS
33-00118EFS-01
HM700A1000
ELECTRODE STEAM HUMIDIFIER
INTRODUCTION
The HM700 is the most advanced residential steam humidifier 
available and provides steady and reliable humidification for a 
home. The humidifier is designed for connection to a steam 
distributor installed in a supply air duct for humidity on 
demand.
IMPORTANT
Read and save these instructions. This guide should 
be kept by the installer, and the Homeowner’s Guide 
should be left with the equipment owner.
Included in the Box
— Steam Humidifier (HM700)
— Distribution Remote Mount Kit (HM700ADISTKIT)
— HumidiPRO Humidistat (H6062A1000)
— Steam Cylinder (one HM700ACYL2 included)
— Rubber drain hose
— Installation Instructions, Homeowner’s Guide and 
Quick Start Guide
Tools Needed
— Screwdriver
— Wrench
— Pliers
— Shut-off water valve
— Water line (LDPE or Copper)
Humidifier Configuration
The HM700 is configured at the factory to operate under most 
conditions without the need to change its configuration.
NOTE: Because the humidifier is factory configured for 
optimal performance, Honeywell strongly 
discourages changes to the jumpers or the 
potentiometer; doing so will void the warranty 
and could damage the humidifier. Contact 
Honeywell Customer Care for further 
information.
Before Installation
1. Ensure that available voltage and phase corresponds 
with humidifier voltage and phase as indicated on 
humidifier’s specification label.
2. Ensure that the dedicated external fuse disconnect is of 
sufficient size to handle the rated amps as indicated on 
the specification label. Refer to local codes.
3. Ensure sufficient clearances will be available as 
described in the Location section on page 5.
4. Ensure steam lines can be routed to duct distributor as 
described in Steam Lines and Condensate Return 
Instructions on page 8.
Table 1. Specifications.
Part Number
Volts
Steam 
Output
GPD
KW
Amps Phase
Max Ext 
Fuse
Standard 
Cylinder
Net/Full 
Weight
lbs. (kg)
Dimensions
in inches
(L x W x H)
HM700A1000
110/120
11
1.4
12.0
1
15 A
CYL2
15 / 20
(7.0 / 9.5)
11.5 x 6.75 x 21.5
220/240
22
2.8