Timberk SWH FSQ1 80 V Manual Do Utilizador
www.timberk.com • electrical storage water heater
5
6. DELIVERY SET
1. Water heater – 1 pc.
2. Anchor bolt – 2 pcs.
3. Pressure safety valve – 1 pc.
4. Discharge pipe – 1 pc.
5. Operation manual and guarantee card – 1 pc.
6. Packing – 1 pc.
2. Anchor bolt – 2 pcs.
3. Pressure safety valve – 1 pc.
4. Discharge pipe – 1 pc.
5. Operation manual and guarantee card – 1 pc.
6. Packing – 1 pc.
Fig. 2
FSQ1 series
1 – the upper composite protective
1 – the upper composite protective
cover
2 – external decorative case
3 – system of flows (3 overflows)
4 – urethane foam heat insulation
2 – external decorative case
3 – system of flows (3 overflows)
4 – urethane foam heat insulation
layer
5 – internal tank
6 – heating element
7 – power cable with GFCI*
8 – thermostat sensor pipe
9 – protective magnesium anode
10 – inlet nozzle with a splitter
11 – the lower composite protective
5 – internal tank
6 – heating element
7 – power cable with GFCI*
8 – thermostat sensor pipe
9 – protective magnesium anode
10 – inlet nozzle with a splitter
11 – the lower composite protective
cover
12 – composite pressure safety
12 – composite pressure safety
valve (make sure to install onto the
cold water supply tube) Pos. A
13 – emergency discharge of
13 – emergency discharge of
surplus water pressure (a small
water leakage is possible from the
emergency discharge hole when
the water heater is operating. It is
normal)
14 – hot water outlet nozzle
15 – the upper part of the hot water
14 – hot water outlet nozzle
15 – the upper part of the hot water
intake tube
* Depending on the product batch, GFCI can
be located not within the power cable electric
plug.
5. WATER HEATER DESCRIPTION
7. WATER HEATER INSTALLATION
Location
1. Electric water heater should be mounted on a firm wall. If the wall is not
1. Electric water heater should be mounted on a firm wall. If the wall is not
robust enough to hold the weight equal to the doubled weight of the total
water heater weight, fully filled with water, then it should be mounted on a
special support.
2. The wall, where the electric water heater is to be mounted, must withstand
2. The wall, where the electric water heater is to be mounted, must withstand
at least the double weight of the water heater, fully filled with water; there
must be no cracks and other damages on the wall. Otherwise it is necessary
to take measures to strengthen the mounting or mount the water heater on
a special support.
3. If a bathroom is too small, the water heater can be installed elsewhere,
3. If a bathroom is too small, the water heater can be installed elsewhere,
unexposed to direct sunlight and unavailable for moisture. However, to
reduce heat losses in pipelines, the location, where a water heater is to be
installed, must be as close to the place, where hot water is used, as possible.
IMPORTANT!
The water heater must be mounted on a vertical wall only
the position, specified in Fig.3 (FSQ1 line – vertically).
Mounting of the appliance in any other position or
vertical or horizontal tilting will inevitably result in
failure of the water heater, emergency situation and is
considered a non-guarantee case by the manufacturer.