g) Press F10 to save and exit. Allow the server to reboot, but watch for the prompt to press F2 in the next step.
Step 3
Enable TPM State in the BIOS.
a) Press F2 during reboot to enter the BIOS setup screens.
b) On the Advanced tab, select Trusted Computing and press Enter to open the TPM Security Device Configuration
window.
c) Set the TPM State option to Enabled.
d) Press F10 to save and exit. Allow the server to reboot, but watch for the prompt to press F2 in the next step.
Step 4
Verify that TPM Support and TPM State are enabled.
a) Press F2 during reboot to enter the BIOS setup screens.
b) On the Advanced tab, select Trusted Computing and press Enter to open the TPM Security Device Configuration
window.
c) Verify that TPM Support and TPM State are set to Enabled.
d) Continue with enabling the Intel TXT feature in the next step.
Step 5
Enable the Intel TXT feature in the BIOS.
a) Choose the Advanced tab.
b) Choose Intel TXT (LT-SX) Configuration to open the Intel TXT (LT-SX) Hardware Support window.
c) Set TXT Support to Enabled.
d) Verify that the following items are listed as Enabled:
• VT Support (default is Enabled)
• VT-d Support (default is Enabled)
• TPM Support
• TPM State
If VT Support and VT-d Support are not enabled, return to the Advanced tab, select Processor Configuration, and
then set Intel (R) VT and Intel (R) VT-d to Enabled.
e) Press F10 to save and exit.
Server Troubleshooting
For general troubleshooting information, see the see the
Server Configuration
Cisco UCS blade servers should be configured and managed using Cisco UCS Manager. For details, see the Configuration Guide
for the version of Cisco UCS Manager that you are using. The configuration guides are available at the following URL: