Cisco Cisco Packet Data Gateway (PDG) Guia Da Instalação

Página de 317
  Cabling the Switch Processor Input/Output Line Card 
Connecting to the CO Alarm Interface  ▀   
 
ASR 5000 Installation Guide  ▄  
 
   
119 
Connecting to the CO Alarm Interface 
The Central Office (CO) Alarm interface utilizes a 10-pin Molex female-connector fro interconnection with the three 
normally closed dry-contact relays. These relays trigger external audio and/or visual indicators for the following three 
alarm levels: 
 
Minor Alarm: This alarm is triggered when a high temperature is detected on a card, causing the fan tray to 
switch its fans to high speed. 
 
Major Alarm: This alarm is triggered by a: 
 
Hardware failure that places a card in an off-line state 
 
Power filter unit failure or removal from the chassis 
 
Failure of one or more fans on either the upper or lower fan tray 
 
Fan tray failure or either fan tray assembly is removed from the chassis 
 
Critical Alarm: This alarm is triggered when a severe degradation in service is detected. For example, if the 
system is supporting a large number of subscribers and packet processing cards are removed thus significantly 
reducing the amount of available CPU and memory resources. 
The CO alarm interface pinout is provided in the following figure and table.  
Figure 38.  SPIO CO Alarm Interface Pinouts 
 
Table 37. 
SPIO CO Alarm Interface Pinouts 
Pin
 
Signal
 
Major Alarm - Normally closed  
Major Alarm - Common  
Major Alarm - Normally open  
Minor Alarm - Normally closed 
Minor Alarm - Common  
Minor Alarm - Normally open 
Critical Alarm - Normally closed 
Critical Alarm - Common  
Critical Alarm - Normally open 
10 
Not used