  Applying Power and Verifying the Installation 
Verifying the Installation  ▀   
 
ASR 5000 Installation Guide  ▄  
 
   
161 
Table 50. 
SMC Run/Fail LED States 
Color
 
Description
 
Troubleshooting
 
Green 
Card powered with no 
errors detected 
None needed.  
Blinking 
Green 
Card is initializing and/or 
loading software 
This is normal operation during boot-up.  
Red 
Card powered with error(s) 
detected 
Errors were detected during the POSTs. It is likely that the errors were logged to the 
system's command line interface during boot. Refer to the System Administration 
Guide
 for troubleshooting information. 
None 
Card is not receiving 
power 
Verify that the POWER LEDs on the PFUs are green. If they are not, refer to 
 for troubleshooting information. 
Verify that the power source is supplying ample voltage and current to the chassis. 
Verify that the card is properly installed per the instructions in this document. 
If all of the above suggestions have been verified, it is possible that the SMC is not 
functional. Please contact your service representative. 
 
SMC Active LED States 
The Active LED on the SMC indicates that the software is loaded on the card and it is ready for operation. For the SMC 
installed in slot 8, this LED is illuminated green during normal operation. For the SMC installed in slot 9, this LED is 
off during normal operation. 
The possible states for this LED are described in the following table. If the LED is not green, use the troubleshooting 
information in the table to diagnose the problem. 
Table 51. 
SMC Active LED States 
Color
 
Description
 
Troubleshooting
 
Green 
Card is active 
None needed for the SMC in slot 8. If green for the SMC in slot 9, verify 
that the SMC in slot 8 is installed properly according to the instructions in 
this document.  
Blinking 
Green 
Tasks or processes being migrated 
from the active SMC to the 
redundant/secondary SMC 
Verify that the Standby LED on the redundant SMC is also blinking green. 
If so, there is an issue with the active SMC. 
None 
Card is not receiving power 
OR 
Card in Standby Mode 
Verify that the Run/Fail LED is green. If so, the card is receiving power 
and POST test results are positive. If it is off, refer to 
 for troubleshooting information. 
Check the state of the Standby LED. If it is green, the card is in standby 
mode.