Applying Power and Verifying the Installation   
▀  Verifying the Installation 
 
 
▄  ASR 5000 Installation Guide 
168 
   
Figure 54.  SPIO LEDs 
 
SPIO Run/Fail LED States 
The SPIO’s Run/ Fail LED indicates the overall status of the card. This LED is illuminated steady green for normal 
operation. 
If the LED is not green, use the troubleshooting information in the table to diagnose the problem. 
Table 59. 
SPIO Run/Fail LED States 
Color
 
Description
 
Troubleshooting
 
Green  Card powered with no 
errors detected 
None needed. 
Red 
Card powered with 
error(s) detected 
Errors were detected during the POSTs. It is likely that the errors were logged to the 
system's command line interface during the boot process.  
Refer to the System Administration Guide for troubleshooting information. 
None 
Card is not receiving 
power 
Verify that the POWER LEDs on the PFUs are green. If they are not, refer to 
 for troubleshooting information. 
Verify that the power source is supplying ample voltage and current to the chassis. 
Verify that the card is properly installed per the instructions in this document. 
If all of the above suggestions have been verified, it is possible that the SPIO is not 
functional. Please contact your service representative.