Cisco Cisco ONS 15454 SDH Multiservice Provisioning Platform (MSPP)

Página de 73
 
40
Release Notes for Cisco ONS 15454 SDH Release 5.0.6
OL-8285-01
  New Features and Functionality
SNMP
CSCeg45934
When NMS sends a query to retrieve E4 Line PM parameters ES, SES, UAS and CV for an E4 interface 
on an STM1E12 card, SNMP does not show PM counts for E4 interfaces. On an STM1E12 card, Ports 
9-12 can be configured as either STM1 or E4. If any of the ports from 9-12 are configured as E4 and an 
SNMP get request is sent to the node to retrieve E4 line PM parameters, SNMP will not show any data 
for E4 PM parameters. To avoid this issue, use other management interfaces to query E4 parameters. This 
issue is resolved in Release 5.0.2.
CSCec75857
There is no SNMP return value for dsx1TotalTable when you configure an ONS 15454 with DSX 1 day 
stats, then query the node. This issue is resolved in Release 5.0.
TL1
CSCeg87471
Do not set the TID for an ENE to more than 19 characters. Setting the TID for an ENE to 20 characters 
or more and then issuing a TL1 command on the GNE to execute on the ENE will result in TL1 agent 
connectivity issues on the ENE. Specifically, if you set the TID on the ENE to 20 characters, reboot the 
TCC, then try to connect to that ENE from a GNE this will result in a loss of TL1 connectivity to the 
GNE. This issue is resolved in Release 5.0.2.
New Features and Functionality
This section highlights new features and functionality for Releases 5.0.x. (Release 4.7 features are also 
included for ease of access.) For detailed documentation of each of these features, consult the user 
documentation.
New Hardware
TCC2P Card
The Advanced Timing, Communications, and Control Plus (TCC2P) card is an enhanced version of the 
TCC2 card. The primary enhancements are Ethernet security features and 64K composite clock BITS 
timing (SONET only).
The TCC2P card performs system initialization, provisioning, alarm reporting, maintenance, 
diagnostics, IP address detection/resolution, SONET SOH DCC/GCC termination, and system fault 
detection for the ONS 15454. The TCC2P also ensures that the system maintains Stratum 3 (Telcordia 
GR-253-CORE) timing requirements. It monitors the supply voltage of the system. 