Connecting the Input/Output  Signals 
 
 
27 
 
Note: Proper  cables are required  for reliable  Ethernet  operation;  to run up to a 
maximum segment  length  of 100 m and up to 100baseT, the cable has to comply with 
the EIA/TIA Category  5 (or higher)  wire  specifications, and for 1000baseT, Category 
6 is required.  For EMC protection,  shielded  cables must be used. 
1  Connect  an RJ-45 cable between  the Ethernet  connector  on the D9824 receiver 
and the Ethernet  port of your PC. 
2  Set up the IP address on the D9824 receiver  (via the front panel display). For 
information  on setting up the IP address via the front panel, see  Setting up for 
Network  Connection
  (on page 13). 
 
Connecting the ASI Output 
Connect  the output signal from the D9824 receiver  ASI OUT connector.   
Use a Belden  “Brilliance”  cable with  foil/braid construction.  The shield must 
provide  99% or better  shielding  effectiveness.   
The equipment  after the D9824 receiver  could be a Cisco D9887 HDTV Receiver. 
 
External Alarm System Connector 
The D9824 receiver  and Alarm relay functionality.  See Connecting  the Cue Tone/Cue 
Trigger Interface
  (on page 29) for more information  on Cue Tone  and Cue Trigger 
equipment  connections.  These outputs are user-configurable  via the Setup Menu  on 
the front panel. 
The Alarm output connector  is a 15-pin sub-D female connector.  The following 
diagram shows the connector  and the pin allocation table for the Alarm output pins. 
The connector  pin states depend on the selected Relay Mode.  The Relay Mode is set 
on the front panel via the Main:  Setup: Outputs menu. 
 
Changing the Relay Mode for Alarm Monitoring 
The Alarm relay  is a program  relay that can be configured  to provide  programmed 
responses  for alarms, warnings,  cue trigger  states for ad-insertion  equipment,  or a 
cue tone output for connection  to ad-insertion  equipment.  As a default, the Alarm 
Relay is configured  for Alarm mode. 
1  On the front panel menu, go the Main: Setup: Outputs, and select  Cueing
2  Use the down arrow  key to scroll through  the menu to Relay  Mode. 
3  Change  the state to Alarm and press the Select key to save the new  setting. As a 
result, the rear panel connector  pin states will change  to that shown  in the table 
below  for Alarm mode.