Cisco Cisco C880 M4 Server

Página de 83
CHAPTER 6 Error Notification and Maintenance (Contents, Methods, and Procedures) 
6.2 Troubleshooting 
44 
 
C122-E175-01EN 
Mode 
Meaning 
Cold System Maintenance (breaker on) 
[Stopped for work (standby)] 
For maintenance work performed while the system 
power is off and the AC power supply is on 
Cold System Maintenance (breaker off) 
[Stopped for work (AC off)] 
For maintenance work performed while the system 
power is off and the AC power supply is off 
TABLE 6.2 Maintenance mode functions 
Item 
Operation 
mode 
Maintenance mode 
Hot System 
Cold 
System 
(breaker 
on) 
Cold 
System 
(breaker 
off) 
Power supply 
operation 
Administrator 
Permitted 
Permitted 
Suppressed 
Suppressed 
Field 
engineer 
Suppressed 
Suppressed 
Permitted 
Permitted 
Wake On LAN 
(WOL) 
Permitted 
Permitted 
Suppressed 
Suppressed 
Calendar function 
Permitted 
Permitted 
Suppressed 
Suppressed 
OS boot 
Permitted 
Permitted 
Suppressed 
Stops at 
BIOS 
Suppressed 
Stops at 
BIOS 
6.1.4  Maintenance of the MMB 
If the server with single MMB fails in MMB, take actions below.   
1.  Shut down the operating system (LAN) from a remote terminal. (*1) 
2.  Turn off the chassis AC power. 
3.  Replace the MMB. 
4.  Turn on the chassis AC power. 
(*1) If you use only port of MMB to login the operating system, you cannot login to the operating system. 
6.2 
Troubleshooting 
This section describes how to troubleshoot system problems. 
6.2.1  Troubleshooting overview 
The following shows the basic procedure for troubleshooting.