CA92344-0879-01 
 
  Table 8.2.2-1 
Item 
Setting values 
URL 
http://<Maintenance IP Address>:<http port#> or   
https://<Maintenance IP Address>:<https port#> 
 
This depends on the system configuration. 
http port#:Default(8081) 
https port#:Default(432) 
Username 
Account username 
Password 
Account password 
 
(3) Enter Maintenance Mode.   
See Appendix B.1.1, "Enabling maintenance Mode 
(4) Confirm the mounting locations of the PSUs. See table 8.2.2-2. 
(5) Remove FAN units at the mounting locations of PSUs. 
See Appendix C.11, “FANU 
 
Do not remove more than a FAN unit at the same time.   
 
(6) Mount the PSU. See Appendix C.8 PSU 
. 
(7) Install the power cable to the main unit. See Table 8.2.2-2. 
Table 8.2.2-2 
Unit type 
Power Supply configuration 
Refer to   
"Input Power Systems" 
Cisco C880 M4 
200V   
Non-redundant power supply 
200V   
Redundant power supply 
200V   
Dual power feed   
 
(8) Turn on AC power of the added PSUs.     
(9) Navigation Bar [System]  →  Click on Sub Menu [System Setup]. 
  The window shown in “System Setup” appears. 
 
(10) Change the appropriate radio buttons under [Power Feed Mode] and [PSU Redundant Mode]. 
     See Appendix B.7, “Redundant Power Supply and Dual Power Feed Configuration   
(11) Change Maintenance Mode disabled. See Appendix B.1.2,” Disabling maintenance mode