Cisco Cisco UCS C3160 Rack Server Ficha De Dados

Página de 86
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
22
CONFIGURING the SERVER
STEP 4
SELECT RAID CONFIGURATION
The RAID controller choices are:
(1) Embedded RAID (on motherboard)
(2) Mezzanine RAID controller cards (not supported in 1-CPU configurations)
(3) PCIe RAID controllers
Cisco can provide factory-configured RAID systems depending on the RAID controller chosen and 
the number of drives ordered. Factory-configured RAID options are listed with each RAID card 
description.
Select RAID Options
Select one of the following (these choices are dependent on the number of CPUs installed):
One embedded RAID upgrade option for internal drives, or
One mezzanine RAID controller for internal drives, or
One RAID controller for external drives, or
One RAID controller for internal drives, or
NOTE:  If you do not select a mezzanine card, a PCIe RAID controller, or one of the 
embedded RAID upgrade options, you will have an embedded SATA-only RAID 
controller that supports up to four SATA-only drives (RAID 0, 1, 10)
NOTE:  When creating a RAID volume, follow these guidelines:
Use the same capacity for each drive in the volume
Use either all SAS drives or all SATA drives
Use either all HDDs or all SSDs
NOTE:  The number of RAID groups (virtual drives) supported per controller is as 
follows:
Embedded RAID = 8
LSI MegaRAID 9271-8i, or 9271CV-8i RAID controller card = 64
LSI MegaRAID 9285CV-8e, or 9286CV-8e RAID controller card = 64
Cisco UCSC RAID SAS 2008M-8i Mezzanine Card = 16
NOTE:  The RAID configuration options listed in 
 are not available 
if you choose embedded RAID (in this case, you must configure RAID yourself using 
separate software).