CONFIGURING the SERVER
STEP 4
SELECT RAID CONFIGURATION
The RAID controller choices are:
(1) Embedded RAID (on motherboard)
(2) Mezzanine RAID controller cards (not supported in 1-CPU configurations)
(3) PCIe RAID controllers
Cisco can provide factory-configured RAID systems depending on the RAID controller chosen and
the number of drives ordered. Factory-configured RAID options are listed with each RAID card
description.
the number of drives ordered. Factory-configured RAID options are listed with each RAID card
description.
Select RAID Options
Select one of the following (these choices are dependent on the number of CPUs installed):
■
One embedded RAID upgrade option for internal drives, or
■
One mezzanine RAID controller for internal drives, or
■
One RAID controller for external drives, or
■
One RAID controller for internal drives, or
NOTE: If you do not select a mezzanine card, a PCIe RAID controller, or one of the
embedded RAID upgrade options, you will have an embedded SATA-only RAID
controller that supports up to four SATA-only drives (RAID 0, 1, 10)
embedded RAID upgrade options, you will have an embedded SATA-only RAID
controller that supports up to four SATA-only drives (RAID 0, 1, 10)
NOTE: When creating a RAID volume, follow these guidelines:
■
Use the same capacity for each drive in the volume
■
Use either all SAS drives or all SATA drives
■
Use either all HDDs or all SSDs
NOTE: The number of RAID groups (virtual drives) supported per controller is as
follows:
follows:
■
Embedded RAID = 8
■
LSI MegaRAID 9271-8i, or 9271CV-8i RAID controller card = 64
■
LSI MegaRAID 9285CV-8e, or 9286CV-8e RAID controller card = 64
■
Cisco UCSC RAID SAS 2008M-8i Mezzanine Card = 16
NOTE: The RAID configuration options listed in
if you choose embedded RAID (in this case, you must configure RAID yourself using
separate software).
separate software).