CPU Removal and Installation (“pick n place”) Tool Set
The Pick n Place tool set includes two tools:
Pick and pull cap tool - used to pull off the plastic protective cap covering an empty CPU socket and 
to remove or lift a CPU processor without touching it
Pick and place tool - used to install a CPU in its socket without damage. Must be used each time a 
CPU is installed in a UCS “M3” server.
Instructions for using this tool set are found at the following link:
Thermal Grease (with syringe applicator) for CPU to Heatsink Seal
Thermal grease must be applied to the top of the CPU where it comes in contact with the heat sink. 
Instructions for applying thermal grease are found at:
Air Baffle Replacement Kit
Air baffles are designed to direct airflow through the server to maintain server temperature at a safe 
operating level. The UCS B22 M3 server comes shipped with two identical air baffles covering the DIMM 
socket areas of the server. These baffles must always remain installed during server operation. The Air 
Baffle Replacement Kit includes the two (identical) air baffles needed for one UCS B22 M3 server. For 
instructions on how to remove and replace the air baffles, see the following link:
NOTE:  When you purchase a spare CPU, the Pick n Place Toolkit is included.
CAUTION:  Use only the thermal grease specified for this server 
(UCS-CPU-GREASE=). Thermal grease for other systems may have 
different thermal conductivity properties and may cause overheating if 
used in the B22 M3 server. DO NOT use thermal grease available for 
purchase at any commercial electronics store. If these instructions are 
not followed, the CPU may overheat and be destroyed.
NOTE:  When you purchase a spare CPU, the thermal grease with syringe applicator 
is included.