Cisco Cisco UCS C210 M2 General-Purpose Rack Server White Paper

Página de 51
11   © 2016 Cisco and/or its affiliates. All rights reserved.
Configuring RAID 5
Create a single RAID 5 drive group with two virtual drives using eight 1.2-TB SAS drives. In the Integrated Management 
Controller, create two virtual disks with sizes of 7.6-TB and 34.19-GB in a single underlying RAID 5 drive group as shown in 
the following steps and in Figures 11 through 14.
1.  In the navigation pane, click the 
Storage tab.
2.   On the Storage tab, select 
Cisco 12G SAS Modular RAID Controller and in the configuration pane, select the Controller 
Info tab.
3. Select 
Create Virtual Drive from Unused Physical Drives and create the virtual drive.
4.  After virtual drive creation is complete, fully initialize the virtual drives.
Figure 11.  Creating Virtual Drive from Unused Physical Drives