Cisco Cisco ONS 15600 Multiservice Switching Platform (MSSP)
2
Release Notes for Cisco ONS 15600 Release 7.0.4
OL-12391-01
Changes to the Release Notes
Changes to the Release Notes
This section documents supplemental changes that have been added to the Release Notes for Cisco ONS
15600 Release 7.0.4 since the production of the Cisco ONS 15600 System Software CD for Release
7.0.4.
15600 Release 7.0.4 since the production of the Cisco ONS 15600 System Software CD for Release
7.0.4.
Caveats
Review the notes listed below before deploying the ONS 15600. Caveats with tracking numbers are
known system limitations that are scheduled to be addressed in a subsequent release. Caveats without
tracking numbers are provided to point out procedural or situational considerations when deploying the
product.
known system limitations that are scheduled to be addressed in a subsequent release. Caveats without
tracking numbers are provided to point out procedural or situational considerations when deploying the
product.
Hardware
ONS-SE-2G-xx.x
The ONS-SE-2G-xx.x complies with performance criteria for all intra-facility fiber cables and
connectors per Telcordia GR-326-CORE, Issue 3 Sept. 1999. Cisco recommends the following approved
suppliers for intrafacility fiber cables to use with this product:
connectors per Telcordia GR-326-CORE, Issue 3 Sept. 1999. Cisco recommends the following approved
suppliers for intrafacility fiber cables to use with this product:
•
Volex
•
Fitel
•
Sumitomo
•
Fujikura
•
Tyco
Maintenance and Administration
Caution
VxWorks is intended for qualified Cisco personnel only. Customer use of VxWorks is not recommended,
nor is it supported by Cisco's Technical Assistance Center. Inappropriate use of VxWorks commands can
have a negative and service affecting impact on your network. Please consult the troubleshooting guide
for your release and platform for appropriate troubleshooting procedures. To exit without logging in,
enter a Control-D (hold down the Control and D keys at the same time) at the Username prompt. To exit
after logging in, type “logout” at the VxWorks shell prompt.
nor is it supported by Cisco's Technical Assistance Center. Inappropriate use of VxWorks commands can
have a negative and service affecting impact on your network. Please consult the troubleshooting guide
for your release and platform for appropriate troubleshooting procedures. To exit without logging in,
enter a Control-D (hold down the Control and D keys at the same time) at the Username prompt. To exit
after logging in, type “logout” at the VxWorks shell prompt.
CSCsb82218
When a PPM or PIM is physically removed from a node yet remains provisioned, the CTC display shows
as blue, as though it was only preprovisioned. Because the PPM or PIM is physically removed, and thus
raises an improper removal alarm, CTC should display the alarmed entity as yellow. This issue is
resolved in Release 7.2.
as blue, as though it was only preprovisioned. Because the PPM or PIM is physically removed, and thus
raises an improper removal alarm, CTC should display the alarmed entity as yellow. This issue is
resolved in Release 7.2.