Cisco Cisco MGX 8880 Media Gateway

Página de 29
 
15
Release Notes for Cisco MGX 8880 Software Release 5.3.00
Part Number OL-8892-01 Revision B0, October 23, 2006
  Limitations, Restrictions, and Notes for 5.3.00
PORT SCT 6—Policing disabled, used for PNNI ports.
CARD and PORT SCT 52—Policing enabled on PNNI, disabled on MPLS
PORT SCT 53—Policing disabled on PNNI and MPLS
PORT SCT 54— Policing enabled on PNNI, disabled on MPLS
PORT SCT 55—Policing disabled on PNNI and MPLS
The following are checksums for the new AXSM-E SCT file:
AXSME_SCT.PORT.5.V1: Checksum is = 0x793c56d0= 2033997520
AXSME_SCT.PORT.6.V1: Checksum is = 0xe92db9a5= 3912087973
AXSME_SCT.PORT.52.V1: Checksum is = 0x51241b7a= 1361320826
AXSME_SCT.PORT.53.V1: Checksum is = 0x34bdf8b9= 884865209
AXSME_SCT.PORT.54.V1: Checksum is = 0xb5df2c5c= 3051301980
AXSME_SCT.PORT.55.V1: Checksum is = 0xc5d355c8= 3318961608
AXSME_SCT.CARD.5.V1: Checksum is = 0x793c56d0= 2033997520
AXSME_SCT.CARD.52.V1: Checksum is = 0x972810ac= 2535985324
Limitations, Restrictions, and Notes for 5.3.00
This section includes information about limitations, restrictions, and notes pertaining to MGX 
Release 5.3.00. 
Due to granularity limitations in the AXSM-E hardware, cell traffic does not reach the configured 
peak cell rate (PCR) rate when weighted fair queuing (WFQ) is enabled. You must configure 
connections that have WFQ enabled with a PCR of 101 percent of the actual required rate. Available 
bit rate (ABR) has the same Qbin priority as the unspecified bit rate (UBR) in the SCT tables. In this 
case, ABR and UBR share excess bandwidth if WFQ is enabled.
The VXSM cards, when installed for the first time or after clearing the slot configuration, create a 
default configuration. The creation of a default configuration involves writing large amount of data 
to the hard disk in the node.
When multiple VXSM cards are installed simultaneously or the configuration of multiple VXSM 
slots are cleared simultaneously, one or more VXSM cards could fail to be installed. This potential 
failure results in following recommendations (refer to CSCed12646):
Install VXSM cards, using the setrev command, one at a time. Install another VXSM after the 
earlier one is completely installed and is Active.
Clear the VXSM slot configuration using the clrsmcnf command (with no option where the slot 
primary software version is preserved) one at a time. Wait until the VXSM rebuilds after 
clearing its slot configuration (without clearing the slot primary software version) before 
clearing the slot configuration of another VXSM slot.
Upgrading the VISM-PR Image
If you are upgrading the VISM-PR image to Release 3.2.1x or later and the PXM1E or PXM45 image 
from Release 4.x or earlier to Release 5.x, first upgrade the VISM-PR cards. Then, upgrade the PXM1E 
or PXM45 cards in the same node.