5.2 Humidity
6. Agency Requirements
6.1 Safety Certification.
6.2 AC Input Leakage Current
IInput leakage current from line to ground will be less than 3.5mA rms. Measurement will be 
made at 240 VAC and 60Hz.
7. Reliability
7.1 Mean Time Between Failures (MTBF)
The MTBF of the power supply shall be calculated utilizing the Part-Stress Analysis 
method of MIL217F or Bell core RPP. The calculated MTBF of the power supply 
shall be greater than 100,000 hours under the following conditions:
Full rated load
120V AC input
Ground Benign
25°C
Table 16 –Safety Certification
UL 60950-1 2000Edition, IEC60950-1, 3rd Edition EU 
Low Voltage Directive (73/23/EEC) (CB) TUV, CCC
FCC Part15 ( Radiated & Conducted Emissions ) CISPR 
22,3rd Edition / EN55022: 1998 + A1: 2000)
EN61000-3-2:2000
EN61000-3-3: 1995 + A1: 2002
EN55024: 1998 + A1: 2001 and A2: 2003 
-IEC 61000-4-2
-IEC 61000-4-3
-IEC 61000-4-4
-IEC 61000-4-5
-IEC 61000-4-6
-IEC 61000-4-11
Product Safety: 
RFI Emission:
PFC Harmonic:
Flicker:
Immunity against:
-Electrostatic discharge:
-Radiated field strength:
-Fast transients:
-Surge voltage:
-RF Conducted
-Voltage Dips and Interruptions
Operating Humidity Range:
20% ~ 90%RH non-condensing
Non-Operating Humidity Range:
5% ~ 95%RH non-condensing