Cisco Cisco Agent Desktop 8.5

Página de 8
3
Release Notes for Cisco Agent Desktop 7.0 (1)
  Resolved Caveats
Resolved Caveats
cSCsc46525
Symptom:
When an ECC variable (for example, ICM Call Variable 1) from a CAD desktop 
is populated with data that is greater than the permitted CTI OS desktop variable 
length (greater than 39 characters) none of the CAD desktop ECC variables are 
transferred to the CTI OS desktop. ECC variables within the CTI OS ECC variable 
length limit (less than 39 characters) are transferred.
Conditions:
Call Scenario: a CAD agent transfers a call to a CTI OS agent with ECC variables.
Workaround:
Limit the ECC variables to less than or equal to 39 characters. 
CSCsc47302
Symptom:
When a CAD Agent receives a PSTN call and wants to consult transfer the call to 
another agent, the Transfer button on the “Transfer A Call” window goes to 
grayed-out (inactive) if the CAD agent waits over 15 seconds to perform a consult 
transfer. The Transfer A Call window reflects the “Consult call failed” message in 
the bottom left-side corner. If the CAD Agent A selects the Transfer button before 
15 seconds expire then the consult transfer is successful. 
Conditions:
Occurs when an agent wants to transfer a caller to another agent. The agent 
performs a consult transfer and waits more than 15 seconds before completing the 
transfer. 
Workaround:
The CAD Agent A can use the Alternate feature on the Transfer a Call window.
CSCsc77053
Symptom:
No data or the normal error message appears when an administrator tries to access 
the Enterprise Configuration, IPCC Configuration, or Personnel nodes in Desktop 
Administrator when they are being accessed by another user.
Conditions:
Desktop Administrator is loaded on a PC running Windows 2000 Professional.
Workaround:
None. It is normal for the administrator to not be able to access these nodes if 
another user has them open, but no error message appears the way it should.
Table 2
Resolved caveats for CAD 7.0(1)
DDTS Number
Explanation
CSCsb34949
Voice Contact: work flows do not execute.
CSCsb54112
Error while trying to configure NT authentication for Logger/AW access.
CSCsb54231
IPPA service and Enterprise service cannot connect to CTI service.
CSCsb73423
Incorrect name for backup tool in Cisco CAD Installation Guide 7.0(0).
CSCsb77005
CDBRTool switches.Incomplete list of switch options.
Table 1
Open caveats for CAD 7.0(1) (continued)
DDTS Number
Explanation