xConfiguration Audio Input Microphone [1..8] VideoAssociation 
VideoInputSource
Select the video input connector to associate the audio source with.
Requires user role: ADMIN
Default value: 1
USAGE:
xConfiguration Audio Input Microphone 
n
 VideoAssociation VideoInputSource: 
VideoInputSource
where
n
: Unique ID that identifies the microphone input. Range: 1..8
VideoInputSource
: 1/2/3/4/5
Select the video input connector to associate the audio source with.
xConfiguration Audio Input Microphone [1..8] Level
Define the level of the Microphone input connector. 
See the Audio Level table in the Physical Interface Guide for Cisco TelePresence SX80 for a 
complete overview of the values represented in dB.
Requires user role: ADMIN
Default value: 58
USAGE:
xConfiguration Audio Input Microphone 
n
 Level: 
Level
where
n
: Unique ID that identifies the microphone input. Range: 1..8
Level
: Integer (0..70)
Select a value between 0 and 70, in steps of 1 dB.
xConfiguration Audio Input Microphone [1..8] Mode
Disable or enable audio on the microphone connector.
Requires user role: ADMIN
Default value: On
USAGE:
xConfiguration Audio Input Microphone 
n
 Mode: 
Mode
where
n
: Unique ID that identifies the microphone input. Range: 1..8
Mode
: Off/On
Off: Disable the audio input microphone connector.
On: Enable the audio input microphone connector.
xConfiguration Audio Input Microphone [1..8] Type
The microphone connectors are intended for electret type microphones. The microphone 
connector can be set to line or microphone mode.
Requires user role: ADMIN
Default value: Line
USAGE:
xConfiguration Audio Input Microphone 
n
 Type: 
Type
where
n
: Unique ID that identifies the microphone input. Range: 1..8
Type
: Line/Microphone
Microphone: Select Microphone when you have 48 V Phantom voltage and the 
pre-amplification is On.
Line: Select Line when you have a standard balanced line input. The phantom voltage 
and pre-amplification is Off.