Cisco Cisco TelePresence MX700 Manual De Manutenção

Página de 141
D15119.02 MX700 and MX800 Administrator Guide TC7.2, AUGUST 2014.  
www.cisco.com — Copyright © 2014 Cisco Systems, Inc. All rights reserved. 
90
Cisco TelePresence MX700 and MX800 
Administrator Guide
Peripherals settings
Peripherals Pairing CiscoTouchPanels RemotePairing
In order to use Cisco Touch 10 (touch panel) as user interface for the video system, Touch 10 
must be either directly connected to the video system or paired to the video system via LAN. 
The latter is referred to as remote pairing.
Remote pairing is allowed by default; you must switch this setting Off if you want to prevent 
remote pairing.
Requires user role: ADMIN
Value space: <Off/On>
Off: Remote pairing of Touch 10 is not allowed.
On: Remote pairing of Touch 10 is allowed.
Example:
 Peripherals Pairing CiscoTouchPanels RemotePairing: On
Peripherals Profile TouchPanels
Set the number of touch panels that are expected to be connected to the video system. This 
information is used by the video system’s diagnostics service. If the number of connected touch 
panels does not match this setting, the diagnostics service will report it as an inconsistency. 
Note that only one Cisco Touch controller is supported in this version.
Requires user role: ADMIN
Value space: <NotSet/Minimum1/0/1/2/3/4/5>
NotSet: No touch panel check is performed.
Minimum1: At least one touch panel should be connected to the video system.  
0-5: This number of Touch controllers should be connected to the video system. 
Example:
 Peripherals Profile TouchPanels: Minimum1
Contents
Introduction
Web interface
System settings
Setting passwords
Appendices
System settings