  Restoring a Firepower Management Center to Factory Defaults
Firepower Management Center Getting Started Guide
12
sudo /usr/local/sf/bin/configure_console.sh vga
To access the appliance using the physical serial port: 
sudo /usr/local/sf/bin/configure_console.sh serial
To access the appliance using LOM via SOL: 
sudo /usr/local/sf/bin/configure_console.sh sol
3.
To implement your changes, reboot the appliance by typing 
sudo
 
reboot
.
The appliance reboots.
Using the Web Interface to Redirect the Console Output
Procedure
1.
Select 
System > Configuration.
2.
Select 
Console Configuration.
3.
Select a remote console access option:
Select 
VGA 
to use the appliance's VGA port. This is the default option.
Select 
Physical Serial Port
 to use the appliance's serial port, or to use LOM/SOL on a Management Center.
If you selected 
Physical Serial Port
, the LOM settings appear. 
4.
To configure LOM via SOL, enter the appropriate settings:
DHCP Configuration
 for the appliance (
DHCP
 or 
Static
).
IP Address 
to be used for LOM. The LOM IP address must be different from the management interface IP 
address of the appliance.
Netmask 
for the appliance. 
Default Gateway 
for the appliance. 
5.
Click 
Save
.
Remote console configuration for the appliance is saved. If you configured Lights-Out Management, you must 
enable it for at least one user; see 
Restoring a Firepower Management Center to Factory 
Defaults
Cisco provides ISO images on its Support Site for restoring, or reimaging, Firepower Management Centers to their 
original factory settings.
For more information, see the following sections: