Introduction
Before You Begin Troubleshooting
Identification of an Issue
With the Battery Backup Unit (BBU)
With the Disk Drive
With the RAID Controller
Solution
Introduction
There is a firmware issue on the FireSIGHT Management Center (FMC) FS4000 platform that may
impact RAID and storage management. This document describes a process to validate if a failure
is due to the disk, or with the RAID controller.
Before You Begin Troubleshooting
Before you start troubleshooting, please determine the following items:
Is the system down?
Is the system up, but unreachable?
Is the RAID controller hung?
If the RAID controller is hung, any commands attempted may return an IO error.  You may be able
to access the FMC FS4000 through Secure Shell (SSH), but may not be able to run any
commands.
You can confirm this by trying to SSH to the FS4000. If the system is unreachable or you can log
in but unable to run any commands, the issue is most likely with the disk controller or drive.
The following section describes different types of failure on a FireSIGHT Management Center
FS4000 model (Product ID: FS4000-K9/FS4000-BASE-K9).
Identification of an Issue
With the Battery Backup Unit (BBU)
If a "Disk Degraded" Critical Health Alert is triggered, check if there is any issue with the Battery
Backup Unit (BBU).
1. Run the following command and verify the output. Check the highlighted lines as reference.
admin@FireSIGHT:~$ sudo MegaCLI -AdpBbuCmd -GetBbuStatus -aALL
BBU status for Adapter: 0
BatteryType: CVPM02