Cisco Cisco MDS 9000 NX-OS Software Release 5.0
22
Cisco MDS 9000 Family Release Notes for Cisco MDS NX-OS Release 5.0(7)
Downgrading Your Cisco MDS SAN-OS Software Image
•
Disable all features not supported by the downgrade release. Use the show incompatibility system
downgrade-image command to determine what you need to disable.
downgrade-image command to determine what you need to disable.
•
Use the show install all impact downgrade-image command to determine if your downgrade will
be nondisruptive.
be nondisruptive.
•
Be aware that some features impact whether a downgrade is disruptive or nondisruptive:
–
Fibre Channel Ports: Fibre Channel ports can be nondisruptively downgraded without
affecting traffic on the ports. See
affecting traffic on the ports. See
releases.
–
SSM: Intelligent services traffic on the SSM, such as SANTap, NASB, and FC write
acceleration, is disrupted during a downgrade. SSM Fibre Channel traffic is not.
acceleration, is disrupted during a downgrade. SSM Fibre Channel traffic is not.
–
Gigabit Ethernet Ports: Traffic on Gigabit Ethernet ports is disrupted during a downgrade.
This includes IPS modules and the Gigabit Ethernet ports on the MPS-14/2 module, the
MSM-18/4 module, and the MDS 9222i switch. Those nodes that are members of VSANs
traversing an FCIP ISL are impacted, and a fabric reconfiguration occurs. iSCSI initiators
connected to the Gigabit Ethernet ports lose connectivity to iSCSI targets while the downgrade
is in progress.
This includes IPS modules and the Gigabit Ethernet ports on the MPS-14/2 module, the
MSM-18/4 module, and the MDS 9222i switch. Those nodes that are members of VSANs
traversing an FCIP ISL are impacted, and a fabric reconfiguration occurs. iSCSI initiators
connected to the Gigabit Ethernet ports lose connectivity to iSCSI targets while the downgrade
is in progress.
–
IVR: With IVR enabled, you must follow additional steps if you are downgrading from Cisco
SAN-OS Release 2.1.(1a), 2.1(1b), or 2.1.(2a). See the
SAN-OS Release 2.1.(1a), 2.1(1b), or 2.1.(2a). See the
for these instructions.
–
FICON: If you have FICON enabled, the downgrade path is different. See the
.
Note
A downgrade from NX-OS Release 4.2(1b) to SAN-OS Release 3.3(1x) is not supported on MDS
switches, when FC-Redirect based applications, such as Data Mobility Manager or Storage Media
Encryption, are configured in the fabric if either of the following conditions are satisfied:
switches, when FC-Redirect based applications, such as Data Mobility Manager or Storage Media
Encryption, are configured in the fabric if either of the following conditions are satisfied:
1.
A target for which FC-Redirect is configured is connected locally and there are Generation 1
modules with ISLs configured in the switch.
modules with ISLs configured in the switch.
2.
A host, for which FC-redirect is configured, is connected locally on a Generation 1 module.
If these conditions exist, remove the application configuration for these targets and hosts before
proceeding with the downgrade.
proceeding with the downgrade.