Cisco Cisco Industrial Wireless 3702 Access Point Guia Da Instalação
18
Cisco IW3702 Access Point Getting Started Guide
Installation
3.
Connect the other end of the power cable to the DC power source using the power source wiring instructions.
The PWR connector pinout descriptions are in
.
Connecting the Antennas
Connect each antenna based on:
.
Installation information in
Connecting to Access Point Ports
This section describes connecting the access point to PoE.
Warning:
For connections outside the building where the equipment is installed, the following ports must be
connected through an approved network termination unit with integral circuit protection.
10/100/1000 Ethernet Statement 1044
10/100/1000 Ethernet Statement 1044
Connecting to the PoE IN or PoE OUT Port
1.
Use shielded cables with a M12 X-Code plug to connect to the PoE IN or PoE OUT ports.
Note:
Ethernet cables must have an internal shield around the signal wires. There must be a contiguous ground
between the connector shell that interfaces with the IW3702 and the connector shell on the far end of the cable.
Maximum cable length should not exceed 100 meters.
Maximum cable length should not exceed 100 meters.
2.
Connect the PoE IN cable to the PoE IN port, or the PoE OUT cable to the PoE OUT port by turning the cable
clockwise, as shown in
clockwise, as shown in
.
1
Power cable and PWR connector