Cisco Cisco Email Security Appliance C170 Referências técnicas

Página de 316
R E P O R T I N G C O N F I G
C H A P T E R   3 :   T H E   C O M M A N D S :   R E F E R E N C E   E X A M P L E S
 249
Configure Storage Limit for Reporting Data (C-Series only)
- MAILSETUP - Configure reporting for the ESA.
- MODE - Enable centralized or local reporting for the ESA.
[]>
Code Example 3-147 
reportingconfig
 - Configure storage limit for centralized reporting data
esa01-vmw1-tpub.qa> reportingconfig
Choose the operation you want to perform:
- MAILSETUP - Configure reporting for the ESA.
- MODE - Enable centralized or local reporting for the ESA.
[]> mailsetup
SenderBase timeout used by the web interface: 5 seconds
Sender Reputation Multiplier: 3
The current level of reporting data recording is: unlimited
No custom second level domains are defined.
Legacy mailflow report: Disabled
Choose the operation you want to perform:
- SENDERBASE - Configure SenderBase timeout for the web interface.
- MULTIPLIER - Configure Sender Reputation Multiplier.
- COUNTERS - Limit counters recorded by the reporting system.
- THROTTLING - Limit unique hosts tracked for rejected connection 
reporting.
- TLD - Add customer specific domains for reporting rollup.
- STORAGE - How long centralized reporting data will be stored on 
the C-series before being overwritten.
- LEGACY - Configure legacy mailflow report.
[]> storage
While in centralized mode the C-series will store reporting data for 
the M-series to collect.  If the M-series does not collect that data 
then eventually the C-series will begin to overwrite the oldest data 
with new data.
A maximum of 24 hours of reporting data will be stored.
How many hours of reporting data should be stored before data loss?
[24]> 48
SenderBase timeout used by the web interface: 5 seconds
Sender Reputation Multiplier: 3
The current level of reporting data recording is: unlimited
Code Example 3-146 
reportingconfig
 - Enabling centralized reporting