Cisco Cisco Aironet 340 Ethernet Bridges Guia Do Utilizador

Página de 218
4 - 12   Aironet 340 Series Bridge 
When started, the radio is put in a special mode, in which it will scan 
through all the allowed frequencies, pause on each one and measure the 
percentage of the time that the carrier detect line for the radio is busy.
CAUTION: Since this test uses a special operating mode all current asso-
ciations to the unit will be lost during the test.
The display is a scaled bar graph with the frequencies along the bottom. 
The percentage utilization represented by the highest bar is given in the 
bottom line.
Running the Echo Tests (Multicast, Unicast, Remote)
An echo test consists of sending a number of packet between units. The 
packets are sent with a proprietary protocol, which the target nodes rec-
ognize and will echo back to the test source along with information 
about how well it received the packets.
                       CARRIER BUSY / FREQUENCY 
          
*       
*         
*       
*           *         
*           *    
*           *    
*           *       
* *         *   
* *         *       
* * * * * * * * * * *  
1 1 2 2 3 3 4 4 5 5 6        
2 7 2 7 2 7 2 7 2 7 2         
          
Highest point = 9% utilization   
Enter space to redisplay, q[uit] :