5 - 2    Aironet 340 Series Bridge
Using the Configuration Ethernet Menu
The Ethernet Port is configured using the Configuration Ethernet Menu. 
To access this menu, select Configuration from the Main Menu then 
select Ethernet from the Configuration Menu. 
 Activating/Disabling the Ethernet Port (Active) 
NOTE: Do not activate the Ethernet Por t until all other parameters have 
been set correctly.
The active option is used to enable or disable the Ethernet Port connec-
tion. The default setting for active is “On”. 
The active option should be disabled if the port on the Aironet 340 
Series Bridge is not going to be used. This informs the software not to 
route packets to the port and stops the use of processing power for scan-
ning for Ethernet activity.
Setting the Maximum Frame Size (Size)
The size option allows you to increase the maximum size of the frames 
transmitted to and from the Ethernet infrastructure. Do not set the maxi-
mum frame size greater than 1518 unless you are running proprietary 
software that allows you to exceed this maximum. You may set the value 
between 1518 to 4096.
           Configuration Ethernet Menu 
    Option       Value      Description
1 - Active     [ on   ]   - Connection active
2 - Size       [ 1518 ]   - Maximum frame size
3 - Port       [ auto ]   - Port selection
Enter an option number or name, “=” main menu, <ESC> previous menu
>_