Cisco Cisco TelePresence MX700 Nota De Lançamento
Introduction software version TC5.1.5
Cisco TelePresence System C/EX/SX/MX Series Software Release Notes
Page 78 of 194
Introduction software version TC5.1.5
This release note describes the features and capabilities included in the Cisco TelePresence System
C/MX/SX/EX-Series codec software version TC5.1.5 released on November 23
C/MX/SX/EX-Series codec software version TC5.1.5 released on November 23
rd
2012.
Note: Please read the known limitations section if you use TMS to upgrade your system from any
release prior to TC4.0.0
release prior to TC4.0.0
From TC5.0.0 the C/EX/MX-Series supports provisioning and basic call functionality with
Cisco Unified Communications Manager (CUCM) version 8.6 and above. It also supports
Cisco Discovery Protocol (CDP) for easy deployment in CUCM environments. When
provisioning mode is set to CUCM the system will try to use Voice VLAN if available in your
network. When in other provisioning modes it will try to use Data VLAN.
Please be aware that in future releases Voice VLAN will be set to ‘Auto’ as per Cisco
best practice. If you are using Cisco switches you need to prepare your network so
that network services (VCS, TMS, etc.) is reachable from your Voice VLAN.
best practice. If you are using Cisco switches you need to prepare your network so
that network services (VCS, TMS, etc.) is reachable from your Voice VLAN.
Replacing a directly connected (EX-series or MX-series) or a Touch panel connected to
Ethernet port 2 (C40,C60 and C90) without restarting the system will leave the Touch panel
in an unusable state. A spinning “Connecting” wheel will be displayed and after
approximately 2 minutes a manual pairing dialog will appear.
To replace the Touch panel successfully: Power off the system. Swap the Touch panels.
Power on the system. The Touch panel will come up, and if necessary download software
from the system it is connected to. CSCud33527
Ethernet port 2 (C40,C60 and C90) without restarting the system will leave the Touch panel
in an unusable state. A spinning “Connecting” wheel will be displayed and after
approximately 2 minutes a manual pairing dialog will appear.
To replace the Touch panel successfully: Power off the system. Swap the Touch panels.
Power on the system. The Touch panel will come up, and if necessary download software
from the system it is connected to. CSCud33527
Hardware compatibility
Please see section in the latest release notes for updated information (top of document).