Cisco Cisco TelePresence MX700 Guia Do Utilizador

Página de 37
D15029.01 Troubleshooting Guide TC6.0, April 2013. 
Copyright © 2013 Cisco Systems, Inc. All rights reserved. 
36
CUCM CApF
OK
There are no outstanding CUCM provisioning operations.
problem
There is a pending operation: OpErATiON please take action.
resolve
There is a problem with the CApF setup. please refer to the CApF setup here: 
CUCM CApF
OK
No message.
problem
WArNiNG - There was a notice with the last request.
resolve
Follow link and check settings: 
Valid release Key
OK
The system has a valid release key for the current software.
problem
The system requires a valid release key. please add a release key.
resolve
The current release key is not valid for the software loaded. Check that the 
correct software is loaded – usually TC not TCNC (non-crypto version that 
requires new key) and that you have entered the key correctly. 
Administrator password
OK
A password has been set on the administrator account.
problem
The system requires an administrator password. please configure the admin user.
resolve
A password for admin user has not been set and system is using the default 
(no password). Set a password – login on web interface as 
admin, click 
User: 
admin
 and select 
Change Password
.
Self-diagnostics
OK
problem
Error while trying to run self-diagnostics.
resolve
You may see this message shortly after starting a system. Try to re-run the 
diagnostics to see if this is cleared.
System Temperature
OK
The system is running at an acceptable temperature.
problem
The system temperature is X°C, nearing the warning threshold of 85°C
resolve
Ensure that  the system has adequate ventilation and cooling. if the system 
temperature exceeds 85°C, it will shut down to prevent damage. if the 
environmental conditions are ok and you are still getting this message, please 
open a support ticket.
Echo Cancellation Configuration
OK
No message.
problem
The Echo Cancellation delay has been altered to X. Consider resetting it 
back to 0.
resolve
This setting rarely needs changing. Echo cancellation should only be disabled 
if you are using an external echo cancellation device. 
Multistream Configuration
OK
No message.
problem
Multistream has been enabled. Consider disabling it.
resolve
This setting is experimental and should not be enabled for normal use. Currently 
it will cause you problems with Sip calls. Disable it.
Do not disturb mode
OK
Do not disturb is turned off
problem
Do not disturb is turned on. Until this is turned off, the system cannot accept calls.
resolve
A warning that you have this enabled and therefore incoming calls will not be 
seen. Turn off to enable incoming calls.
Standby Control
OK
The system goes into standby automatically after X minutes.
problem
The automatic standby control is turned off. This will increase power usage 
and may cause burn-ins on plasma screens if left on for longer periods. 
Consider enabling standby.
resolve
Enable standby. The video signal will stop being sent to the monitor as the 
video system goes into standby. CEC can also be enabled if your monitor 
supports it. As a result, the monitor is shutdown when the video system 
enters standby.
No issues found
OK
The system appears to be in working order.
problem
None
resolve
None
Troubleshooting Guide TC6.0