Global Configuration Mode Commands
▀ threshold aaa-acct-failure
▄ Cisco ASR 5000 Series Command Line Interface Reference
OL-22948-01
threshold aaa-acct-failure
Configures accounting failure thresholds for the system.
Product
PDSN, GGSN, HA, ASN GW
Privilege
Security Administrator, Administrator
Syntax
Default: 0
The high threshold number of accounting failures that must be met or exceeded within the polling interval to
generate an alert or alarm.
The number can be configured to any integer value between 0 and 10000000. A value of 0 disables the
threshold.
The high threshold number of accounting failures that must be met or exceeded within the polling interval to
generate an alert or alarm.
The number can be configured to any integer value between 0 and 10000000. A value of 0 disables the
threshold.
Default: 0
The low threshold number of accounting failures that maintains a previously generated alarm condition. If the
number of failures falls beneath the low threshold within the polling interval, a clear alarm will be generated.
The number can be configured to any integer value between 0 and 10000000. A value of 0 disables the
threshold.
The low threshold number of accounting failures that maintains a previously generated alarm condition. If the
number of failures falls beneath the low threshold within the polling interval, a clear alarm will be generated.
The number can be configured to any integer value between 0 and 10000000. A value of 0 disables the
threshold.
Important:
This value is ignored for the Alert model. In addition, if this value is not configured for the Alarm
model, the system assumes it is identical to the high threshold.
Usage
Accounting failure thresholds generate alerts or alarms based on the number of failed AAA accounting
message requests that occur during the specified polling interval. Accounting requests are counted for all
AAA accounting servers that the system is configured to communicate with.
Alerts or alarms are triggered for accounting failures based on the following rules:
message requests that occur during the specified polling interval. Accounting requests are counted for all
AAA accounting servers that the system is configured to communicate with.
Alerts or alarms are triggered for accounting failures based on the following rules:
Enter condition: Actual number of failures ³ High Threshold
Clear condition: Actual number of failures < Low Threshold
If a trigger condition occurs within the polling interval, the alert or alarm will not be generated until the end
of the polling interval.
Refer to the
of the polling interval.
Refer to the
command to configure the polling interval and the
command to enable thresholding for this value.
Example
The following command configures a high threshold count of 100 AAA accounting failures and low threshold of 25 for
an system using the Alarm thresholding model:
The following command configures a high threshold count of 100 AAA accounting failures and low threshold of 25 for
an system using the Alarm thresholding model: