Cisco Cisco Packet Data Gateway (PDG) Guia De Resolução De Problemas

Página de 5302
Global Configuration Mode Commands   
▀  threshold dcca-unknown-rating-group 
 
▄  Cisco ASR 5000 Series Command Line Interface Reference 
OL-22948-01   
threshold dcca-unknown-rating-group 
Configures the unknown Diameter Credit Control Application (DCCA) Rating Group (content-id) returned by Diameter 
to system thresholds. 
Product
 
ECS 
Privilege
 
Security Administrator, Administrator 
Syntax
 
Disables the threshold for configured alarm and sets the 
 and 
 values to 0. 
Default: 0 
The high threshold number of unknown Rating Group (content-id) sent by Diameter server and received by 
system that must be met or exceeded within the polling interval to generate an alert or alarm. 
The number can be configured to any integer value between 0 and 1044000. 
Default: 0 
The low threshold number of unknown Rating Group (content-id) sent by Diameter server and received by 
system that maintains a previously generated alarm condition. If the number of errors falls beneath the low 
threshold within the polling interval, a clear alarm will be generated. 
The number can be configured to any integer value between 0 and 1044000. 
Important:
  This value is ignored for the Alert model. In addition, if this value is not configured for the Alarm 
model, the system assumes it is identical to the high threshold. 
Usage
 
In the event that the Diameter server sends invalid Rating Groups, content-ids to the system, dcca-unk-
rating-group
 message is generated. 
Unknown Rating Group threshold generates alerts or alarms based on the number of unknown Rating Groups 
received by the system from Diameter server during the specified polling interval. 
Alerts or alarms are triggered for unknown rating groups based on the following rules: 
 
Enter condition: Actual number of unknown rating groups ³ High Threshold 
 
Clear condition: Actual number of unknown rating groups < Low Threshold 
If a trigger condition occurs within the polling interval, the alert or alarm will not be generated until the end 
of the polling interval.